![SMARDY HOME 190 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/smardy/home-190/home-190_instruction-manual_1294977006.webp)
6. First commissioning
Before you open the water supply, please double-check all the hose lines.
These must have been laid absolutely free of kinks.
•
Open the filter flush valve. It is located before the membrane.
•
Open the water supply (shown here in the green circle) and check all the
connections for tightness.
•
Leave the filter flush valve in an open position for approx. 10 minutes.
•
Close the filter flush valve.
•
Open the water tap for 5 min to flush all the lines once again.
•
Subsequently you can enjoy fresh osmosis water
7. Consumables
For your system you need the following replacement filters and membranes:
item N°
Description
Change interval
N° 8
Membrane 50 GPD
Every 24 months
N° 9
Activated carbon afterfilter
Every 6 months
Daily output 190 L
N° 14
Sediment filter
Every 6 months
Just smardy original filters ensure a trouble-free functioning!!