Installation
1.9
Figure 1.13 – Wires position in the connector
Figure 1.14 – Release the cables’ connector
Assembly Procedure
Mount the components following the sequence:
1. Pass the cable through the cover orifice (Figure 1.15);
2. Pass the cable through the base connector orifice (Figure 1.16);
3. The red, white, and black wires should be inserted in the base connector orifice marked by
numbers beside them, look at figure 1.17 e 1.18.
Figure 1.15 – Assembling the cover
Figure 1.16 – Assembling the wire bracket
Orifice to the
white cable
Orifice to the
red cable
Orifice to the
black cable
Figure 1.17 – Inserting the wires in the
connector
Figure 1.18 – Orifice Cable’s Connector with
numbers beside them
Insert the cable connector in the remote Hall's block connector as figure 1.19. The block connector
has internal saliencies that perfectly fit the groove, in order to prevent errors in the assembly. The
cutting pins inside of the block connector will cut the wire insulators and press against them, thus
establishing the electric contact between the cable and the hall sensor’s circuit.
To finish, fasten the cover to the Hall sensor’s connection (figure 1.20).