2.1 Intended purpose
The product is intended for no purposes other than filling compressed air
2.2 Disassembling is prohibited
Disassembling may result in failures or electric shocks. Except for those parts that can be disassem-
bled, it’s not allowed to disassemble any other part. Please contact us immediately if any failure is
found. Don’t repair it by yourself to avoid dangers.
2.3 Confirming input voltage
If AC power supply is used:
First of all, confirm whether the input voltage for the machine is consistent with local supply voltage
(remove the voltage shifter dust cover at the top for confirmation, see the first item on page 7 for
details). Make the input voltage consistent with local supply voltage if they are inconsistent. A short
circuit or fire may be caused and the machine may be damaged in case incorrect input voltage is used.
If DC power supply is used:
Be sure to connect the red wire to the positive pole and the black wire to the negative pole.
2.4 Power cable:
If the power cable is damaged, please use those with the following specifications for replacement. A
fire or damage may be caused if an incorrect power cable is used. Note that the machine is level-I
protection, so it must be connected with grounding terminals.
For areas with supply voltage of 100 – 120V:
UL certified, three-core cable (one is ground wire), American wire gauge No.18, maximum length: 3m,
minimum rated voltage: 125V.
For areas with supply voltage of 220 – 240V:
Conforming to EU/EN and 3C standards, three-core ground cable, maximum length: 3m, minimum rated
voltage: 250V.
2.5 Avoiding electric shocks:
• Don’t unplug or plug the power plug with a wet hand to avoid induced current or electric shocks.
• Be sure to turn off the power switch (“O” position) before unplugging or plugging the cable to prevent
electric shocks.