7 Troubleshooting
7.1 Status Messages
Your inverter can be in various operating states. These are displayed as status messages, which can
vary according to the type of communication.
Message
Description
Balanced
The inverter has disconnected from the power distribution grid or
is limiting its power over a 10-minute average to 4.6 kVA
(in Italy: 6 kVA). The inverter is a part of a 3-phase system with
2 further inverters and is equipped with the SMA Power Balancer
to prevent the formation of unbalanced loads.
Derating
Overtemperature in the inverter. The inverter reduces its output to
prevent overheating. To avoid unnecessary output losses, check
the plant configuration. Inform your installer.
Disturbance, disturbance
Disturbance.
This message appears for safety reasons and ensures that the
inverter does not connect to the power distribution grid.
Inform your installer.
Error
An error has been detected. Inform your installer.
Earthfault
Measurement of the insulation resistance of the small wind turbine
system.
Grid monitoring
Grid monitoring
This message appears during the startup phase before the inverter
is connected to the power distribution grid.
Off Grid
The inverter is in "Island" mode. This mode is specially designed for
operation in an off-grid system.
Offset
Offset adjustment of the measurement electronics.
Stop
Operation interrupted.
Turbine
The inverter is in the operating state "Turbine". This mode is
specially designed for operation on small wind turbine systems.
V-Const
Constant voltage mode.
Waiting
The connection conditions are not (yet) fulfilled.