The correct configuration of the parameters above is absolutely necessary to
guarantee optimum operation with generators from different manufacturers.
Preconditions for changing the operating parameters are described in chapter 6.4
"General setting example” (page 37).
Name
WB 5000
WB 6000
Unit
Description
UpvStart
300
(250 ... 600)
300
(250 ... 600)
V
DC
Defines the voltage at the
moment when the Windy
Boy 5000 / 6000 is ready to
perform a mains supply
synchronization.
UdcWindStart 330
(1 ... 800)
330
(1 ... 800)
V
DC
Defines the voltage at the
moment when the Windy
Boy 5000 / 6000 is ready to
begin feeding power into the
mains supply.
UdcWindMax 550
(1 ... 800)
550
(1 ... 800)
V
DC
Defines the voltage at the
moment when the Windy
Boy 5000 / 6000 begins
feeding maximum power
into the mains supply.
P-Wind-Ramp
500
(10 ... 2000)
500
(10 ... 2000)
W/sec
Controls a delayed startup
of the characteristic curve,
only after the Windy Boy
5000 / 6000 has been
switched on. This avoids the
generator being suddenly
presented with a heavy
load.
T-Start
10
(5 ... 1600)
10
(5 ... 1600)
sec
Start Timer Mains
synchronization.
T-Stop
2
(1 ... 3600)
2
(1 ... 3600)
sec
Stop Timer Aborting the
supply of power and
switching off.
To perform the configuration process, the DC input voltage must be greater
than <UpvStart> and the Windy Boy 5000 / 6000 must be connected to the
mains supply.
Содержание Windy Boy 5000
Страница 2: ......
Страница 4: ...SMA Technologie AG Page 4 WB50_60 11 FE4105 Operating Instructions ...
Страница 12: ...Safety information SMA Technology AG Page 12 WB50_60 11 FE4105 Operating instructions ...
Страница 28: ...Unit description SMA Technology AG Page 28 WB50_60 11 FE4105 Operating instructions ...
Страница 30: ...Setting the display language SMA Technology AG Page 30 WB50_60 11 FE4105 Operating instructions ...
Страница 32: ...Maintenance and care SMA Technology AG Page 32 WB50_60 11 FE4105 Operating instructions ...
Страница 38: ...Turbine operation SMA Technology AG Page 38 WB50_60 11 FE4105 Operating instructions ...
Страница 40: ...Maintenance and care SMA Technology AG Page 40 WB50_60 11 FE4105 Operating instructions ...
Страница 66: ...Stand alone systems SMA Technology AG Page 66 WB50_60 11 FE4105 Operating instructions ...
Страница 68: ...Contact SMA Technology AG Page 68 WB50_60 11 FE4105 Operating instructions ...
Страница 69: ......