DaNGEr!
Electric shock from high voltage at inverter.

Even when no external voltage is present, there can still be high voltages in the device. 

The following work must be carried out by qualified personnel only:

• 

Electrical installation

• 

Repairs

•  Modification

CaUTION! 
risk of injury from touching the enclosure during operation. 

Burns to the body.

• 

Only touch lid and display during operation.

CaUTION!
Yield loss due to poor heat dissipation.

• 

Do not place any objects on the enclosure.

SafETY INSTrUCTIONS

DIaGraM

POWEr DISPLaY

MEaSUrEMENT aCCUraCY

The power and energy of the inverter are displayed in the three fields: Power, Day and Total. The 

display is updated every five seconds.

Power

Current inverter power output fed into the grid.

Day

The energy fed into the grid on this particular day. This means the 

energy total from midnight to the current time.

Total

Total energy which the inverter has fed into the grid during its entire 

operating time.

The inverter energy is shown as a diagram on the display. The 

daily graph is displayed by default. The right-hand flashing bar of 

the diagram represents the current hour. In case the inverter does 

not feed any power into the grid for a prolonged period  (e.g. 

when the wind is calm), a gap is inserted into the graph. The  bar 

for the current hour is updated automatically every five seconds.

After four seconds, the bar goes off for one second and then 

displays the current value.

The display values may deviate from the actual values and must not be used as a basis for invoicing. 

The inverter's measured values are required for the system management and to control the current to 

be fed to the grid. The inverter does not have a calibrated meter.

GraPhIC DISPLaY

PLaNT OVErVIEW

Current output

Daily energy

Total energy generated since the inverter was installed

Text line for displaying an event

Graphical display of the inverter energy

The display updates the values of your small wind turbine every five seconds.

Tapping on the cover:

• Activating the background illumination

• Switching from the energy values of the past 16 feed-in

    hours to daily energy values of the past 16 days

• Switching through the line display

Failure

Contact installer

Switch open: no feeding

Switch closed: feeding

Grid voltage/

current

Bluetooth

 connection with other devices

DC voltage/

current

Grid event number

Event number, small wind turbine system

Event number, inverter

Power reduction due to excessive temperature

• 

Cleaning the fan 

• 

Provide better ventilation for inverter

LED

Green LED is glowing:  Operation

Green LED is flashing:

Network connection conditions not yet reached. 

Red LED is glowing:

Failure: contact installer.

Blue LED is glowing:

The inverter has been incorporated into a 

Bluetooth

 network and can 

communicate with other devices with identical NetID.

Blue LED is flashing:

The inverter was identified with Sunny Explorer by setting the "Find device" 

parameter.

PrODUCT OVErVIEW

Top enclosure lid

Lower enclosure lid

Graphic display

Electronic Solar Switch

LEDs

Serial number

Identification of Windy Boy using type plate