SMA Solar Technology AG
Parameter lists
Technical Description
SI5048-TEN093630
141
19.1.2 Battery Meters (120#)
Number Name
Description
displayed
value
Description
01
BatSoc
Current operating mode
(SOC) in %
02
BatVtg
Battery voltage in V
03
BatChrgVtg
Charging voltage target value in v
04
AptTmRmg
Remaining absorption time in
hh:mm:ss
05
BatChrgOp
Active charging process
Boost
Boost charge
Full
Full charge
Float
Float charge
Equalize
Equalization charge
Silent
Silent Mode
06
TotBatCur
Total battery current of the cluster
in A
07
BatTmp
Battery temperature in °C
08
RmgTmFul
Remaining time until next full
charge in days
09
RmgTmEqu
Remaining time until next
equalization charge in days
10
AptPhs
Absoption phase state
Off
Absorption phase
not active
On
Absorption phase
is active
11
BatSocErr
Estimated error of the charge state
in percent