6 Electrical Connection
SMA Solar Technology AG
Installation Manual
SBxx-1SP-US-40-IA-xx-15
36
5. Lead one end of each network cable from the conduit into the inverter.
6. Put the network plug of each cable into one of the
network sockets of the communication assembly.
D-IN
SPS
A
B
FCC ID: SVF-KP20
IC: 9440A-KP20
Max. 30V DC
USB
SPS
A
B
D-IN
7. Ensure that the network connector is securely in place by pulling slightly on each cable.
8. Connect the other end of the network cable to the energy meter.
6.4
Connecting the Multifunction Relay
6.4.1
Procedure for connecting the multifunction relay
Procedure
See
1.
Select for which operating mode you would like to use the
multifunction relay.
2.
Connect to the multifunction relay according to the operat-
ing mode and the associated connection variant.
see section 6.4.3,
page 37 and see sec-
tion 6.4.4, page 40
3.
After commissioning the inverter, change the operating
mode of the multifunction relay, if necessary.
User manual under
www.SMA-Solar.com
6.4.2
Operating Modes of the Multifunction Relay
Operating mode of multi-
function relay (Mlt.Op-
Mode)
Description
Fault indication (FltInd)
The multifunction relay controls a display device (e.g. a warning
light) which, depending on the type of connection, signals either an
error or the undisturbed operation of the inverter.
Self-consumption (SelfC-
smp)
The multifunction relay switches loads on or off, depending on the
power production of the PV system.
Control via communica-
tion (ComCtl)
The multifunction relay switches loads on or off according to com-
mands transmitted by a communication product.
Battery bank (BatCha)
The multifunction relay controls the charging of the batteries depend-
ing on the power production of the PV system.
ENGLISH