23

Energy Consumption LED

The energy consumption LED is only active if either the bidirectional meter for grid feed-in and 
purchased electricity is connected or one feed-in meter and one purchased electricity meter are 
connected.

Status LED

Further states of the status LED are described in the Section "Troubleshooting" (see Section 9.1.2 
"States of the Status LED", page 52).

BLUETOOTH LED

Further states of the BLUETOOTH LED are described in the Section "Troubleshooting"  
(see Section 9.1.3 "States of the BLUETOOTH LED", page 54).

LEDs on the Network Terminal

Figure 5: LEDs on the network terminal

LED status

Explanation

Glowing green

The household is being supplied with energy from the PV system only.

Flashing green and 
orange intermittently

The household is being supplied with energy from the PV system and from 
the utility grid.

Glowing orange

The household is being supplied with energy from the utility grid only.

LED status

Explanation

Glowing green

The Sunny Home Manager is connected to the devices of the PV system 
and Sunny Portal.

LED status

Explanation

Glowing blue

The BLUETOOTH connection to the devices of the PV system is good.

Position LED

LED status

Explanation

A

Link/Activity 
LED (green)

Glowing

Network connection established

Flashing

Network connection established. Data is being sent or 
received.

Off

No network connection established

B

Speed LED 
(yellow)

Glowing

The data transfer rate is up to 100 Mbit/s.

Off

The data transfer rate is up to 10 Mbit/s.

Содержание HM-BT-10

Страница 1: ...HoMan IA en 17 Version 1 7 ENGLISH Installation Manual SUNNY HOME MANAGER...

Страница 2: ...nty conditions from the Internet at www SMA Solar com Software Licenses The licenses for the software modules used can be found on the CD provided Trademarks All trademarks are recognized even if not...

Страница 3: ...1 4 1 3 LEDs 22 4 1 4 System Requirements 24 4 2 SMA Radio Controlled Socket 25 4 2 1 Functions 25 4 2 2 LED Display 26 5 Preparing for Mounting and Commissioning of the Sunny Home Manager 28 5 1 Prep...

Страница 4: ...rgy Meters with S0 Interface 38 7 3 Replacing Energy Meters 41 7 4 Connecting the Sunny Home Manager to the Router 41 7 5 Connecting a Device to be Controlled via a Data Exchange Protocol 41 7 6 Suppl...

Страница 5: ...e Manager after Resetting the Sunny Home Manager System 64 9 8 Resetting the SMA Radio Controlled Socket to Default Settings 65 10 Decommissioning 66 10 1 Disassembling the Sunny Home Manager 66 10 2...

Страница 6: ...or qualified persons Only persons with the appropriate skills are allowed to perform the activities described in this document see Section 2 3 Skills of Qualified Persons page 13 Further Information L...

Страница 7: ...ate injury 05 Indicates a situation which if not avoided can result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates a requirement for...

Страница 8: ...OOTH Piggy Back Plus BLUETOOTH Piggy Back SMA BLUETOOTH Piggy Back Off Grid BLUETOOTH Piggy Back Off Grid SMA BLUETOOTH Repeater SMA BLUETOOTH Repeater Outdoor BLUETOOTH Repeater Sunny WebBox Sunny We...

Страница 9: ...r property damage Do not use the Sunny Home Manager in systems which include a Sunny WebBox For safety reasons it is not permitted to modify the product or install components that are not explicitly r...

Страница 10: ...uct if they can cause injuries or fires if unintentionally switched on e g iron Only connect loads to the product if they are suitable for the voltage and power range of the wall outlet and the produc...

Страница 11: ...15000TLHE 10 STP 20000TLHE 10 from firmware version 2 10 20 R STP 5000TL 20 STP 6000TL 20 STP 7000TL 20 STP 8000TL 20 STP 9000TL 20 from firmware version 2 00 15 R Inverters with BLUETOOTH Piggy Back...

Страница 12: ...in the Sunny Home Manager system the Sunny Home Manager will no longer query the power data of the SMA inverters directly from the inverters via BLUETOOTH or Speedwire but will receive the power data...

Страница 13: ...ast 500 pulses per kWh Routers SMA Solar Technology AG recommends the use of a router that supports DHCP Other Devices Heat pump Stiebel Eltron WWK 300 Heat pump Tecalor TTA 300 Miele home devices e g...

Страница 14: ...ger indoors and in a dry environment keeping it away from liquids Do not open the plug in power supply 65 0 Risk of injury due to incorrect cable routing Incorrectly routed cables may cause a tripping...

Страница 15: ...l outlet Risk of injury and fire due to unintentional and unattended switching on of loads Loads that are activated via an SMA radio controlled socket unintentionally and while unattended can cause in...

Страница 16: ...included in the scope of delivery Scope of Delivery of SMA Radio Controlled Socket Figure 2 Components included in the scope of delivery Position Quantity Designation A 1 Sunny Home Manager B 1 Plug...

Страница 17: ...out of energy meter data and data from SMA devices with BLUETOOTH or Speedwire communication interface Transmission of data to Sunny Portal Support for increased self consumption Limitation of active...

Страница 18: ...Internet connection to Sunny Portal and sends the read out data to Sunny Portal via a router Using Sunny Portal the Sunny Home Manager enables monitoring of the system a display of the PV energy avai...

Страница 19: ...n In accordance with the PV system operator s specifications and taking the determined time periods into account the Sunny Home Manager controls switch on and switch off of the loads Also SMA radio co...

Страница 20: ...feed in Taking the PV yield forecast and the consumption forecast into account the timing and duration of battery charging are controlled and the battery charge is optimized according to the available...

Страница 21: ...PV system is required to implement grid management services 4 1 2 Type Label The type label clearly identifies the product The type label is located on the back of the product You can read off the fol...

Страница 22: ...ian EMC standards FCC marking The product complies with the requirements of the applicable FCC standards BLUETOOTH Wireless Technology The product has a BLUETOOTH interface Data matrix code 2D code fo...

Страница 23: ...D status Explanation Glowing green The household is being supplied with energy from the PV system only Flashing green and orange intermittently The household is being supplied with energy from the PV...

Страница 24: ...ported web browsers Google Chrome from version 14 0 Microsoft Internet Explorer from version 8 Mozilla Firefox from version 5 Opera from version 11 0 Safari from version 5 0 Recommended display resolu...

Страница 25: ...he Sunny Home Manager Measuring the energy consumption of the connected loads Improving the wireless connection between BLUETOOTH devices Implementing Control Commands of the Sunny Home Manager The Su...

Страница 26: ...play Position Designation Explanation A LED display Displays status operating modes and NetIDs B Touch key Operation of the SMA radio controlled socket LED status Operating mode status of the SMA radi...

Страница 27: ...g the SMA radio controlled socket from the outlet Otherwise the SMA radio controlled socket could be damaged LED status Explanation Glowing blue The BLUETOOTH connection to the Sunny Home Manager is g...

Страница 28: ...of your system determine a free NetID at the planned mounting location of every BLUETOOTH device and make a note of this see Sunny Explorer manual 2 For all devices that are to communicate with the S...

Страница 29: ...utlet The upper horizontal LED glows red for approximately ten seconds then the vertical LEDs glow green for approximately four seconds 2 As soon as the LED display shows 0 keep tapping the touch key...

Страница 30: ...d on the router or modem you might have to adjust the firewall rules On a router or modem with NAT Network Address Translation no port forwarding should be set up This will help prevent potential comm...

Страница 31: ...th of 30 m A minimum distance of of 1 m must be maintained from devices using the 2 4 GHz radio spectrum e g WLAN devices microwave ovens This will prevent reduced connection quality and data transmis...

Страница 32: ...ystem must be commissioned see Section 5 1 Preparing for BLUETOOTH Communication page 28 Procedure 1 Supply the Sunny Home Manager with voltage via the plug in power supply see Section 7 6 1 After app...

Страница 33: ...the screw anchors into the holes 5 Screw in the screws leaving approximately 6 mm protruding from the wall 6 Hook the Sunny Home Manager onto the screws Ensure that the heads of the screws are engage...

Страница 34: ...ED Status display of BLUETOOTH connection D Meter 1 Pin connector for 1 purchased electricity meter with D0 or S0 interface or 1 bidirectional meter with D0 interface for grid feed in and purchased el...

Страница 35: ...of Enclosure Figure 13 Terminal on the right side of the enclosure Left Side of Enclosure Figure 14 Terminal on the left side of the enclosure Position Designation Explanation A USB port Currently wi...

Страница 36: ...ification Description A GND Voltage supply Ground B TX Transmitter output Transmit D0 C RX Receiver input Receive D0 D VCC_D0 8 Volt Voltage supply output Voltage supply for the optical probe Pin Sign...

Страница 37: ...nergy Meters with D0 Interface Additionally required material not included in the scope of delivery Cable with optical probe and 4 pole plug see Section 12 Accessories page 73 Requirements for energy...

Страница 38: ...3 For bidirectional meters for grid feed in and purchased electricity insert the four pole plug into the pin connector Meter 1 3 Use the labels provided to mark each cable with the pin connector and e...

Страница 39: ...h For the function Limitation of active power feed in energy meters with an S0 interface must have the following pulse rates For systems with maximum permitted grid feed in of more than 1 500 W at lea...

Страница 40: ...nto the lower contact pin row For purchased electricity meters insert the four pole plug into the pin connector Meter 1 For feed in meters insert the four pole plug into the pin connector Meter 2 For...

Страница 41: ...olled via a Data Exchange Protocol Devices controlled by the Sunny Home Manager via a data exchange protocol are not connected to SMA radio controlled sockets but are connected to the Sunny Home Manag...

Страница 42: ...2 Supplying the Sunny Home Manager with Voltage via the Top Hat Rail Power Supply As an alternative to the plug in power supply you can supply the Sunny Home Manager with voltage using a top hat rail...

Страница 43: ...DC insulated conductor into contact pin 3 and the DC insulated conductor into contact pin 4 of the four pole plug 9 If no energy meter is connected to the four pole plug insert the four pole plug int...

Страница 44: ...LED intermittently flashes green and orange The status LED is not intermittently flashing green and orange It is possible that the Sunny Home Manager is not correctly connected to the router Ensure t...

Страница 45: ...ample if there is a proxy server in your network or if your router does not support DHCP If the status LED is continuously flashing red or you have to manually configure the IP address in your network...

Страница 46: ...stem Setup Assistant opens 2 Select Next The page User registration opens Registering as a New User in Sunny Portal 1 Activate the field I am not yet registered and select Next 2 Enter the necessary d...

Страница 47: ...ETOOTH and Speedwire devices for the user group Installer If necessary set a uniform system password for all BLUETOOTH and Speedwire devices see Sunny Explorer Help Procedure 1 Activate the field Crea...

Страница 48: ...of the BLUETOOTH and Speedwire devices see troubleshooting see Section 9 3 Errors during Registration in Sunny Portal page 56 or The PV System Setup Assistant lists own and third party devices See tro...

Страница 49: ...y Home Manager system select To the PV system The Sunny Home Manager system opens 5 Enter the system properties see user manual Sunny Home Manager in Sunny Portal Connected energy meter type Drop down...

Страница 50: ...switched on or off in this mode On The connected load can draw electric current Off The connected load cannot draw electric current Manually switched on The SMA radio controlled socket is switched on...

Страница 51: ...ed operating mode 3 To adopt the operating mode wait approximately one second Do not tap the touch key After approximately two seconds the SMA radio controlled socket audibly switches to the selected...

Страница 52: ...nager from the voltage supply and then reconnect see Section 7 6 If the status persists contact the SMA Service Line Flashing red The Sunny Home Manager cannot establish a connection to Sunny Portal I...

Страница 53: ...or at least one device is not connected to the Sunny Home Manager event type Disturbance Corrective measures Call up the event in the system log book of Sunny Portal see user manual Sunny Home Manager...

Страница 54: ...dress line enter e g www SMA Solar com and confirm with the Enter key If the Internet connection is permanently impaired ensure that the router is functioning correctly If necessary contact the Intern...

Страница 55: ...the PV system see Section 5 1 3 page 29 There may already be more than one additional master in your BLUETOOTH network e g Sunny Beam and computer with Sunny Explorer As a result the Sunny Home Manag...

Страница 56: ...he PV System Setup Assistant cannot establish a connection to the Sunny Home Manager It is possible that the Sunny Home Manager is not correctly connected to the router or It is possible that the Sunn...

Страница 57: ...a connection to these inverters during this time Corrective measures Select Skip forward and continue with registration After registration add devices to the system as new devices when there is suffic...

Страница 58: ...possible that the SMA device is not correctly connected to the router or is not supplied with voltage Corrective measures Ensure that the SMA device is correctly connected to the router and supplied w...

Страница 59: ...nload area at www SMA Solar com The router network switch used in the network deactivates the LAN ports when they appear to be inactive in order to save energy As a result it is not possible to establ...

Страница 60: ...pleted Corrective measures Perform a complete reset of the Sunny Home Manager see Section 9 6 It is possible that the Sunny Home Manager is not correctly connected to the router Corrective measures En...

Страница 61: ...gistration without selecting the inverters 2 Once there is daylight and the inverters are switched on log in to Sunny Portal and add the inverters as new devices to the Sunny Home Manager system using...

Страница 62: ...e operating system of your computer or Insert the CD provided into the drive of your computer 3 Start the Sunny Home Manager Assistant by double clicking on the file name 4 Follow the instructions giv...

Страница 63: ...e energy consumption LED are intermittently flashing orange To completely reset the Sunny Home Manager press the reset button until the status LED and the energy consumption LED are intermittently fla...

Страница 64: ...E MANAGER in Sunny Portal Reassigning the Sunny Home Manager to the Sunny Home Manager System via the PV System Setup Assistant Requirement You must be the PV system administrator for user roles and u...

Страница 65: ...to default settings in the following cases You wish to operate the SMA radio controlled socket in a different system You wish to reset the measured values of the SMA radio controlled socket Procedure...

Страница 66: ...work terminal of the Sunny Home Manager 5 Unplug the other end of the network cable from the router 6 If the Sunny Home Manager is mounted on the wall push the Sunny Home Manager upwards and remove it...

Страница 67: ...r Shipping Pack the device for shipment Use the original packaging or packaging that is suitable for the weight and size of the device see Section 11 Technical Data page 68 10 3 Disposing of the Sunny...

Страница 68: ...ce Great Britain Canada Luxembourg Portugal Spain Czech Republic Austria Switzerland USA Mechanical Data Width x height x depth 170 mm x 124 5 mm x 41 5 mm Weight 220 g Voltage Supply Voltage supply P...

Страница 69: ...ng 5 to 95 Degree of protection in accordance with IEC 60529 IP20 Maximum altitude above MSL Mean Sea Level 2 000 m Communication Interface to Other Devices SMA devices BLUETOOTH Speedwire Devices con...

Страница 70: ...x depth 118 mm x 76 mm x 56 mm Weight 156 g Voltage Supply Voltage 100 V to 240 V Frequency 50 60 Hz Maximum current 16 A Minimum power consumption 0 25 W Maximum power consumption 1 5 W Maximum swit...

Страница 71: ...ondensing 5 to 95 Maximum altitude above MSL 3 000 m Communication Interface to Other Devices Sunny Home Manager BLUETOOTH Speedwire Maximum Range BLUETOOTH maximum range in free field conditions 100...

Страница 72: ...Manual TaiyTech TYT251200200EU 3000M Mechanical Data Width x height x depth 92 0 mm x 90 6 mm x 36 0 mm Weight 190 g Voltage Supply Voltage 100 V AC to 240 V AC Frequency 50 60 Hz Maximum current 0 8...

Страница 73: ...the following overview If required you can order these from SMA Solar Technology AG or from your distributor Designation Brief description SMA order number Optical probe Cable with optical probe and f...

Страница 74: ...free for Australia 1800 SMA AUS 1800 762 287 International 61 2 9491 4200 Belgien Belgique Belgi SMA Benelux BVBA SPRL Mechelen 32 15 286 730 Brasil Vide Espa a Espanha esko SMA Central Eastern Europ...

Страница 75: ...bourg Siehe Belgien Voir Belgique Magyarorsz g l sd esko Csehorsz g Nederland zie Belgien Belgi sterreich Siehe Deutschland Per Ver Espa a Polska Patrz esko Czechy Portugal SMA Solar Technology Portug...

Страница 76: ...17 Installation Manual SMA Solar Thailand Co Ltd 66 2 670 6999 SMA Technology Korea Co Ltd 82 2 508 8599 971 2 234 6177 SMA Middle East LLC Other countries International SMA Service Line Niestetal Tol...

Страница 77: ...www SMA Solar com SMA Solar Technology...

Отзывы: