background image

Page 3 

 

A torque chain, ‘S’ hook, nut and bolt are included in this assembly to 

secure your pump during operation. 

1. 

Attach one end of the torque chain over the threaded stem of the 

bolt 

2. 

Thread the whiz nut onto the bolt. Hand-tighten 

3. 

Thread the bolt, chain and nut ‘pre-assembly’ into the threaded 

hole on the underside of the pump. Tighten sufficiently 

4. 

Affix the ‘S’ Hook to your frame (or hitch). Wrap the chain around 

the frame or hitch and ‘S-Hook’ it in place. Make sure this con-

nection is very secure! Not having a good, tight connection may 

result in the pump spinning on your PTO shaft and damaging 

some components of your sprayer 

*** Insure that this connection point will not allow the roller pump to 

spin on the PTO shaft *** 

Torque Chain Attachment to a Roller Pump

 

Strap/Buckle Detail 

Strap Attachment 

to a “Bent” Buckle 

The nylon straps are to be inserted in and out of the slots in the  

buckle, as shown. Be sure the straps are snug before tightening the 

hook bolts. In most cases, it will be necessary to re-tighten the straps 

after filling the tank with liquid. 

 

Caution: 

Never use a metal object or other sharp item for cleaning a 

nozzle tip. It is better to use a nozzle brush (NOT wire brush) or  

compressed air for tip cleaning.

 

 

Conditions of weather and terrain must be considered when setting 

the sprayer. Do not spray on windy days. Protective clothing must be 

worn in some cases

 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The performance of any agricultural chemical depends upon the 

proper application. 

Always fill the tank with a desired amount of water first and then add 

the chemical slowly, mixing as you pour the chemical into the tank. 

You may use the handgun to spraying into the solution in order to 

mix the chemical and water.  

The tips supplied as standard with the sprayer can be used for a 

wide variety of spraying applications. Other tip sizes are available for 

different coverages. The speed and pressure charts shown indicate 

the rates can be changed considerably by changing speed and  

pressure. The pumping system draws solution from the tank through 

the strainer/filter and to the pump. The pump forces the solution  

under pressure to the boom nozzles. 

 

Tank Care & Maintenance 

Warning: 

Do not use the tank as a container for fuel oils, kerosene, 

gasoline or any other petroleum distillate product. All polyolefins are 

softened and permeated by such products. In an enclosed area the 

vaporization of these materials from the outside surface of the tank 

could create a dangerous condition. 

 

The tank should not be used as a pressure vessel nor used with 

chemicals or solutions having a weight of more than 12 pounds per 

gallon. 

 

Store the tank in a dry dark place when not in use. Storage out of 

sunlight will prolong the life of the tank. 

 

Do not drop, strike or kick the tank, especially at low temperatures. 

Tanks become brittle and are subject to cracking at temperatures 

below 20° Fahrenheit. 

 

Maintenance During/After Spraying 

Periodically close the suction line valve and check the strainer and 

clean the screen.  

 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, fill the sprayer tank part way with water. Start the sprayer 

and allow the clear water to be pumped through the plumbing system 

and out through the spray nozzles. Refill the tank about half full with 

plain water and use FIMCO Tank Neutralizer and Cleaner and repeat 

cleaning instructions above (If no tank cleaner is available, you may 

substitute dish soap for this step, about 1-2 oz. per gallon). Flush the 

entire sprayer with the neutralizing/cleaning agent, then flush out one 

more time with plain water. Follow the chemical manufacturer’s dis-

posal instructions of all wash or rinsing water. For the boom (if appli-

cable) remove the tips and screens from the nozzle assemblies. 

Wash these items out thoroughly. Blow the orifice clean and dry. If 

the orifice remains clogged, clean it with a fine bristle (NOT WIRE) 

brush or with a toothpick. Do not damage the orifice. Water rinse and 

dry the tips before storing. 

 

WARNING: 

Some chemicals will damage the pump valves if  

allowed to soak untreated for a length of time! ALWAYS  flush the 

pump as instructed after each  use. DO NOT allow chemicals to sit in 

the pump for extended times of idleness. Follow the chemical manu-

facturer’s instructions on disposal of all waste water from the sprayer. 

 

Winter Storage 

Drain all water out of your sprayer, paying special attention to the 

pump, handgun and valve(s). These items are especially prone to 

damage from chemicals and freezing weather. 

The sprayer should be winterized before storage by pumping a solu-

tion of automotive antifreeze (containing a rust inhibitor) through the 

entire plumbing system. This antifreeze solution should remain in the 

plumbing system during the winter months. When spring time comes 

and you are preparing your sprayer for the spray season, rinse the 

entire plumbing system out, clearing the lines of the antifreeze solu-

tion. Proper care and maintenance will prolong the life of your  

sprayer. 

* *: Available ONLY in complete assembly 

* * 

Strainer 

#5116441 

Содержание 800-3PH150

Страница 1: ...ing on the bottom of the tank Slide the hose clamp to the end of the hose and secure 3 Find the 1 x 36 pump feeder hose Using a good quality thread sealant carefully thread the 1 fitting into the stra...

Страница 2: ...e proper size nozzle for the solution to be sprayed first multi ply the desired GPM or GPA of solution by the rate conversion factor Then use the new converted GPM or GPA rate to select the proper siz...

Страница 3: ...se materials from the outside surface of the tank could create a dangerous condition The tank should not be used as a pressure vessel nor used with chemicals or solutions having a weight of more than...

Страница 4: ...d Adjustable to maintain control of line pressure at any pressure within the valve operating range Selected pressure setting firmly held in place by locknut Extra large passages to handle large flows...

Страница 5: ...Page 5 Exploded View 800 3PH150 5301770 Refer to the parts list next page for part numbers Pump Not Included Shown for reference only...

Страница 6: ...58 150 Gallon Tank 32 Dia x 46 L x 35 H Yellow 1 7 5020099 Hose 3 8 2 Brd x 25 1 30 1 63480 8 Lid w Blue Snap In Vent 1 8 5020570 Hose 1 2 x 48 1 31 5271771 Valve Mount 1 9 5020571 Hose 1 2 x 11 2 32...

Страница 7: ...Page 7 NOTES...

Страница 8: ...ed Warranty you must 1 provide written notice to Fimco Inc of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the f...

Отзывы: