background image

ENGLISH 

OPERATING MANUAL FOR 
RECESSED CEILING LUMINAIRE 
1001015 / 1001016 / 1001017 / 1001018 

  

Read this short manual carefully and keep it accessible for further 
reference! 

  

 

SAFETY MESSAGES

 

  

Disregard of the safety messages may lead to danger of life, burning or 
fire!

 

  Installation, mounting or works on the electrical connection may only be 

carried out by an approved electrician. 

  Do not look directly into the light source. 

  The product may not be modified or converted. 

  Do not hang or fasten anything on the product, especially no decoration. 

  Do not cover the product - provide free air circulation. 

  The luminaire may only be operated with a complete and intact protection 

glass. 

  In case of a malfunction you may NOT touch the product or operate it 

further. Disconnect the product from the power supply by an external 
switch or by the fuse. 
A malfunction exists when: 

  visible damages appear. 

  the product does not work properly (e.g. flickering). 

  smoke, steam or crackling sounds appear. 

  smell of burning is recognisable. 

  an overheating is recognisable (e.g. by discolouration of adjacent 

surfaces). 

Operate the product only after maintenance and examination by an 
approved electrician!

 

  This product is not intended to be used by children. Ensure that children do 

not suffer any harm e.g. by burns from hot surfaces or by electrical shock. 

Additional safety messages are indicated by this symbol: 

 . 

  

USE AS DIRECTED 

  

This product serves exclusively lighting purposes and may: 

  only be used with a voltage of 220-240V ~50Hz. 

  only be installed according to safety class II (two). 

  only be used indoors. 

  only be operated when firmly mounted on a stable, even and tilt-fixed 

surface. 

  only be operated on normally or not flammable surfaces. 

  not be exposed to strong mechanical loads or to strong contamination. 

  

MAINTENANCE AND CARE

 

  

Light source

 

  The light source of this luminaire may only be replaced by the 

manufacturer, an authorized service technician or a comparable qualified 
person. 

  

Care 

 

Disconnect the product from the power supply and let it cool down, before 

you clean the product. 

  Clean the product on a regular basis using a slightly moistened, soft and 

fluff-free cloth. Please also note additional supplied notes on maintanance 
and care. 

STORAGE AND DISPOSAL

 

  

Storage 

  The product must be stored in a dry and clean environment. Do not strain 

the product mechanically during storage. 

 After a damp or soiling storage the product may only be installed after 

checking its condition by an approved electrician. 

Disposal 

(European Union) 

 

  Do not dispose the product with the regular household waste! Products 

marked with this sign must be disposed according to the directive (WEEE, 
2012/19) on electrical and electronic devices at local collection points for such 
devices! 

  

INSTALLATION 

(only by an approved electrician)

 

  

 

Switch off the mains or respectively the connection lead before doing any 

works! 

 

Use only parts, which are supplied with the product or are described as 

accessories! 

 

Inspect the product for loose parts inside the housing. When there are loose 

parts inside the housing and these are not explicitly described the product may 
not be installed or operated. 

 

 

Use the supplied fastening material only when it is suited for the installation 

background. If this is not the case use only fastening material suiting the 
installation background.

 

  

Unpacking 

  Carefully take the product out of the packaging removing any transport 

safeguards. 

  Before disposal of the packaging material make sure that all components of 

the product are removed. 

  

Installation place 

  The product is solely suited for recessed ceiling installation. 

  Note the minimum distances in the ceiling. Minimum distance to each side: 5 

cm. 

  LED react sensitive on high temperatures! Before installation pay attention to 

the expected temperature at the place of operation. 

 The product may only be utilized according to IP20/IP65. 

IP20: Protection against foreign objects > Ø 12,5mm - No protection against 
water. 
IP65: Protection against dust (dust-tight) - Protection against jetted water from 
all directions. 

 Keep a sufficient distance to flammable surfaces. The indicated recess 

depth is the minimum depth. Depending on the installation situation the needed 
recess depth may be larger. This is especially the case, when there are 
flammable materials above the luminaire or to ensure the sufficient ventilation

.

 

 Prepare the power supply lead according to valid rules for outdoor 

installations. 

 Do not seal the product yourself, using additional silicon or another sealant. 

  

 
 
 
 
 
 
 
 
 

Installation steps 

(read completely before installation)

 

 

Dimming:

 Use only a suitable leading-edge phase dimmer / phase cut-off 

dimmer (TRIAC). Note the manufacturers instructions. 

  Install the luminaire as shown in the figure. 

  Mark and cut the opening. Do not damage the mains lead. The 

measurements for the openings are: 

     Ø: 7,0 cm 

  Remove the cover on top of the connection clamp. 

 Electrical 

Connection 

  The product must be able to be separated by an all pole separation 

from the current supply. 

  For electric connection attach the black or brown wire (live conductor) 

of the connection lead with the clamp L and the blue wire (neutral 
conductor) of the connection lead with the clamp N. 

  Attach the cover back on the connection clamp. 

  Direct the luminaire into the opening, with the retaining springs pointing 

upwards. 

 Check if the product functions properly and is securely fixed! 

  

art.-no. 1001015 / 1001016 / 1001017 / 1001018 © 25.08.2017 SLV GmbH, 
Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, 
Tel. +49 (0)2451 4833-0 
Technical Details are subject to change. 

Отзывы: