background image

 
 
 

ENG

       

Instruction Manual for BEAM G9

 

1.    Use as directed: 

This product serves exclusively lighting purposes and may: 

 

only be used with a voltage of 

230V ~50Hz

 

not be operated indoors. 

 

not be exposed to strong mechanical loads or to strong 
contamination. 

 

only be installed and operated after a condition inspection if the 
product is dirty or has been moistened through storage. 

 

not be modified or converted. 

 If these points named above are not adhered to, a short circuit or 

electrical shock may occur! 
 

2.    Technical Data: 

 

 

 

 

 

Operating voltage: 

230V ~50Hz 

 

Safety class: 

 

Safety type: 

 

IP 44 

 

 

Bulb: 

  QT14,G9, 

max. 

60W 

Dimensions (L/W/H): 

8/8/15,3 cm 

Weight:   1,15 

kg 

 

Importeur:  

SLV 

Elektronik 

GmbH 

 

IP 44

: Protection against foreign objects > Ø 1,0mm - Protection against 

splashing water from all directions. 

 

3.    Installation 

 

The electric connection may be executed only by an electric expert 

who is familiar with the valid directives!

 

 

Attention:

 

Switch off the power of the mains supply line or 

respectively of the connection lead before doing any works

Use only 

parts, which are supplied with the product or are described as accessories! 
Otherwise the product or the installation might not be sufficiently safe.

 

 

Installation place: 

The product is suited for 

wall installation

Make sure that the product is mounted on a 

stable, even and tilt-fixed 

background

.  

The 

light exit

 should be placed at least so far from the illuminated surface, 

as indicated as 

minimum distance

 on the type plate of the luminaire: 

0,5 

m

Pay special caution

 to easily inflammable objects (e.g. foliage). 

 

Separate Installation Steps 

 

Remove the mounting plate from the housing by loosening the two 
screws on the sides (1). 

 

Determine the place of installation and mark the holes to be drilled. Note 
that the cable outlet of the mains supply corresponds with the cable inlet 
of the fixture. Do not damage the power supply line, e.g. by drilling, 
screws or strong bending. 

 

Direct the power supply line through the cable inlet on the mounting 
plate(2). 

 

Fasten the mounting plate to the mounting surface (3). 

Electrical Connection 

 

The product must be able to be separated by an all pole separation from 
the current supply. 

 

Equip the three wire ends with protective tubes(4). 

 

For electric connection attach the black or brown wire (live conductor) of 
the mains supply with the 

clamp L

 and the blue wire (neutral conductor) 

of the mains supply with the 

clamp N

. The green-yellow wire (protective 

conductor) of the mains supply has to be tightly screwed into the 

earth 

clamp

 

 of the product (5).

 

 

 

Inserting the bulb: 

Use a piece of fabric to insert the bulbs. Do not 

touch them with bare fingers. Stick the bulb into the socket. 

 

Now fasten the housing back on the mounting plate. 

Do not forget to 

apply the toothed washers! 

Pay attention that the gasket is properly 

seated.

 

 

Ensure that the light fixture holds securely! 

 

The product is now ready for operation. 

 

4. Operation

Information for the user: 

Operate the product only if it is working correctly. Switch off the product 
with a malfunction immediately and operate it again only after examination 
by an electrical specialist. This is the case, when: 

 

visible damages appear. 

 

the product does not work. 

 

smoke, steam or crackling sounds appear. 

 

an overheating is recognisable. 

Repairs of  the product or work on mains voltage-prominent sections may 
only be carried out by qualified electricians. 

 

Attention:

 Here exists mortal danger from an electric shock! 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

How to avoid failure and fire risk: 

 

Do not cover the product - provide free air circulation! 

 

Do not hang or fasten anything on the product, especially no decoration. 

 

Replace damaged protection glasses immediately!

 

 Never let children play unsupervised with electric products! Children 

can not always estimate dangers in dealing with electric energy correctly. 
 

The following enviromental influences may have unwanted effects on 
the surface of the product: 

 

acid rain and sour soil 

 

high salt content in the air 

 

thawing salt 

 

cleaning agents 

 

other chemical substances (e.g. herbicides) 

Protect the product by adequate means to avoid unwanted changes of the 
surface. 

Cleaning tip

: Switch off power! Clean the product with a damp 

cloth. 

 

What is to do if a bulb is defect or does not work? 

 

Disconnect the product from power

, before you exchange the bulbs. 

 

 

Caution

: Let the bulb cool down first before replacement – otherwise 

considerable risk of injury exists because of the hot surface. 

 

Replace the bulbs only with bulbs of the same data like socket, power 
and capacity. Every other sort of bulb can lead to damages of the light. 

 

Replacing the bulb

: see Installation. 

 

 5.    What else has to be considered? 

Disconnect the product from power

, before you… 

 

clean or maintain the product. 

 

do any works on the product or its components (electric expert). 

227064/65     01/2006   

 by SLV Elektronik GmbH  

Technical Details are subject to change.  

Duplication prohibited ! 

 

 
 
 

F  

         

Mode d'emploi pour 

BEAM G9

 

1.     A utiliser comme indiqué : 

Ce produit ne sert qu’à éclairer: 

 

il est prévu pour une tension de 

230V ~50Hz. 

1

4

5

3

2

L N

 

ne doit pas être exploité dans les zones intérieures.  

 

il ne doit être soumis ni aux efforts mécaniques importants ni à un 
encrassement important. 

 

il ne doit être utilisé qu’après examen si le produit a été stocké dans un 
entrepôt humide ou sale. 

 

il ne doit pas être modifié. 

 Un non-respect de ces points peut causer un court-circuit ou une 

décharge électrique! 
 

2.    Informations techniques: 

 

 

Tension d'alimentation: 

230V ~50Hz 

 

Classe de protection: 

Degré de protection: 

IP 44 

 

 

Ampoule: 

 

QT14,G9, max. 60W 

Dimensions (L/L/H): 

8/8/15,3 cm 

Poids:   1,15 

kg 

 

Importeur:  

SLV 

Elektronik 

GmbH 

 

IP 44

: Protection contre les corps étrangers durs > Ø 1,0 mm - Protection 

contre les éclaboussures provenant de toutes les direction. 
 

3.    Installation 

 

La connection électrique doit être exécutée par un professionnel, 

lequel est familier des normes en vigueur!

 

 

Attention: Mettez l’alimentation électrique ou le raccordement au 

secteur hors tension avant de travailler!

  

Utilisez seulement des pièces qui ont été livrées avec le produit ou qui sont 
uniquement décrites comme accessoires ! Sinon, l’installation ainsi que le 
produit ne peuvent pas être garantis. 

Lieu d'installation 

Ce produit est fait pour un montage 

au mur. 

Veillez à ce que le produit soit 

monté de manière 

stable et résistante au basculement. 

La distance entre 

la sortie de lumière

 et la face illuminée devrait au moins 

être tant que

 la distance minimale

 indiquée sur l’étiquette du type du 

lumière: 

0,5 m

Soyez prudent

 avec les matières inflammables (comme 

rideaux etc.). 

 

Etapes successives pour installer le luminaire 

 

Enlevez la plaque de montage de la lampe en dévissant les deux vis 
latérales(1). 

 

Déterminez l’emplacement du montage et marquez les trous de fixation : 
l’entrée du câble de la lampe doit correspondre à la sortie du câble du 
réseau électrique. Soyez attentif à ce que le câble d'alimentation ne soit 
pas endommagé.

 

 

Faites passer l’adduction à travers le joint (2).

 

 

Fixez la plaque de montage à la face de montage(3).

 

Содержание BEAM G9

Страница 1: ...ittels Benutzen Sie ein Tuch um Leuchtmittel einzusetzen nicht mit den Fingern berühren Stecken Sie das Leuchtmittel auf die Fassung Befestigen Sie nun wieder die Leuchte das Gehäuse an der Montageplatte Zahnscheiben nicht vergessen Achten Sie auf den korrekten Sitz der Dichtung Achten Sie auf den sicheren Halt der Leuchte Das Produkt ist nun betriebsbereit 4 Betrieb Informationen für den Betreibe...

Страница 2: ...sts mortal danger from an electric shock How to avoid failure and fire risk Do not cover the product provide free air circulation Do not hang or fasten anything on the product especially no decoration Replace damaged protection glasses immediately Never let children play unsupervised with electric products Children can not always estimate dangers in dealing with electric energy correctly The follo...

Страница 3: ...éctrica 2 Datos técnicos Tensión de servicio 230V 50Hz Clase de protección I Modo de protección IP 44 Luminaria QT14 G9 max 60W Dimensiones L A AL 8 8 15 3 cm Peso 1 15 kg Importador SLV Elektronik GmbH IP 44 Protección contra cuerpos extraños sólidos Ø 1 0mm contra salpicaduras de agua procedentes de todas las direcciones 3 Montaje La conexión eléctrica sólo puede llevarse a cabo por un electrici...

Страница 4: ...u vervolgens het montageplaat op het montagevlak 3 Elektrische aansluiting Het product moet door een veelpolige scheiding van het elektriciteitsnet gescheiden kunnen worden De draadeindjes moeten met de beiliegende beschermende slangen voorzien worden 4 Voor de elektrische aansluiting verbindt u de zwarte of bruine draad buitenleiding van de aansluitleiding met klemmetje L en de blauwe draad neutr...

Отзывы: