SignBOX II
Installation Guide for 701946-(X)WD201, 701946-(X)WS201
PAGE 1 OF 4
WARNING:
Risk of electrical shock. New installation and LED Retrofit Kit installation requires knowledge of sign
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Follow all NEC and local
codes. SignBOX II is not suitable for submersion or direct exposure to water for extended periods of time.
AVERTISSEMENT:
Risque de choc électrique. La nouvelle installation et l’installation du kit de modification à LED
nécessitent la connaissance des systèmes électriques de signalisation. Si non qualifié, ne tentez pas l'installation.
Contactez un électricien qualifié. Suivez tous les codes NEC et locaux. SignBOX II ne convient pas à la submersion ni
à l’exposition directe à l’eau pendant de longues périodes.
For New Installation, proceed with Step
1 below. For Retrofit Installations, begin
with Retrofit Instructions on page 3.
2.
Components list:
• SignBOX
II
assemblies
Double-sided assemblies:
model numbers 701946-(X)WD201
Single-sided assemblies:
model numbers 701946-(X)WS201
•
SloanLED 12 V Class 2 output power supply
(refer to "
SloanLED Power Supply Guide for
Sign Products
" for appropriate model numbers)
• UL approved 18 AWG (1 mm
2
) or larger
diameter supply wire
• UL approved wire connectors appropriate
for wire gauge used
•
SignBOX
II
mounting hardware (as needed):
Clamps (P/N 410155), Couplers (P/N 401330),
and Brackets (P/N 401309)
• #8 (M4) self-drilling/self-tapping tek screws
(required to pierce through strap), minimum
length 5/8" (16 mm)
• Optional: Electrical grade silicone, nylon zip
ties, double-stick mounting tape
ATTENTION: Only install SignBOX II
when ambient temperature is above
5° C (41° F).
1. Tools required:
Measuring tape,
wire strippers, gloves, cutting tool (sheet
metal shears/snips, scissors, utility knife),
drill, and screwdriver.
New Installation
4.
Cutting product:
Cut straps (along dashed
lines) and wires between modules to obtain
required length.
Tip:
Before cutting wires,
refer to Joining Product section.
3. Measure sign cabinet to determine
quantities of SignBOX
II
.
Y
X
NOTE:
To minimize the potential for shadows
in applications when using frame support tubes,
mount modules or frame support tubes such that
the tubes are centered in between modules and
at a depth that will not directly interfere with the
beam angle of the LEDs.
Use SignComp Adjustable Frame Brace (P/N
5357) or equivalent.
SignBOX
II
modules
Frame Support
(Tension Bar)
Cabinet Face