background image

SignBOX II

Installation Guide for 701946-(X)WD201, 701946-(X)WS201

PAGE 1 OF 4

WARNING: 

Risk of electrical shock. New installation and LED Retrofit Kit installation requires knowledge of sign 

electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Follow all NEC and local 
codes. SignBOX II is not suitable for submersion or direct exposure to water for extended periods of time.

AVERTISSEMENT: 

Risque de choc électrique. La nouvelle installation et l’installation du kit de modification à LED 

nécessitent la connaissance des systèmes électriques de signalisation. Si non qualifié, ne tentez pas l'installation. 
Contactez un électricien qualifié. Suivez tous les codes NEC et locaux. SignBOX II ne convient pas à la submersion ni 
à l’exposition directe à l’eau pendant de longues périodes.

For New Installation, proceed with Step 

1 below. For Retrofit Installations, begin 

with Retrofit Instructions on page 3.

2. 

Components list:

 

• SignBOX 

II

 assemblies 

 

Double-sided assemblies:

 

  model numbers 701946-(X)WD201 

  Single-sided assemblies:

 

  model numbers 701946-(X)WS201

 • 

SloanLED 12 V Class 2 output power supply  

  (refer to "

SloanLED Power Supply Guide for  

  Sign Products

" for appropriate model numbers)

  •  UL approved 18 AWG (1 mm

2

) or larger  

  diameter supply wire

  •  UL approved wire connectors appropriate  

  for wire gauge used

 • 

SignBOX 

II

 mounting hardware (as needed):  

  Clamps (P/N 410155), Couplers (P/N 401330),  

  and Brackets (P/N 401309)

  •  #8 (M4) self-drilling/self-tapping tek screws 

    (required to pierce through strap), minimum  

  length 5/8" (16 mm)

  •  Optional: Electrical grade silicone, nylon zip  

  ties, double-stick mounting tape

ATTENTION: Only install SignBOX II 

when ambient temperature is above

 

5° C (41° F).

1.  Tools required:

 Measuring tape, 

  wire strippers, gloves, cutting tool (sheet  

  metal shears/snips, scissors, utility knife),  

  drill, and screwdriver.

New Installation

4.

  Cutting product:

 Cut straps (along dashed 

lines) and wires between modules to obtain 

required length. 

Tip:

 

Before cutting wires, 

refer to Joining Product section.

3.  Measure sign cabinet to determine   

 

quantities of SignBOX 

II

.

Y

X

NOTE: 

To minimize the potential for shadows 

in applications when using frame support tubes, 

mount modules or frame support tubes such that 

the tubes are centered in between modules and 

at a depth that will not directly interfere with the 

beam angle of the LEDs. 

Use SignComp Adjustable Frame Brace (P/N 

5357) or equivalent.

SignBOX 

II 

modules

Frame Support

(Tension Bar)

Cabinet Face

Отзывы: