background image

60W2 12 VDC Power Supply

Installation Guide for PN 701507-60W2 – NEC Class 2 Output

PAGE 1 OF 2

1.  

Tools required:

 Wire strippers,  

  drill, and screwdriver.

2.  

Supplies required:

 Conduit and 

electrical enclosure for power 

supply (if not placed in a sign made 

from enclosure rated material), 

#8 or #10 pan head screws, 

UL Listed PLTC cable, UL Listed 

electrical wire connectors 

(e.g., wirenuts), silicone.

3. 

Power Supply: 

Identify primary  

  wires, secondary wires, and 

  location of mounting tabs.

4.  

Mount Power Supplies:

 

Use mounting tab in corner to 

secure power supply. 

NOTE:

 Power supply operating temperature is -40º C to 60º C. To ensure adequate 

ventilation, mounting power supplies without a secondary enclosure is recommended. 

Space power supplies by standard knockout locations 3/4 in (19 mm) minimum. 

If secondary enclosure is used (transformer can), power supply spacing to other 

heat producing components must have 4 in (102 mm) of space on each side and 

2 in (51 mm) minimum to top of enclosure. Ensure power supplies are not overloaded 

by verifying output current is less than 5 DC Amps. The use of photo-cells or timing 

device is recommended to make sure power supplies are off during day light hours, 

when sign illumination is not needed. Higher daytime temperatures and unnecessary 

operation may shorten power supply lifetime.

12 VDC Output

(Red & Black)

Mounting Tabs

Primary Wires

5.  

Configure Power Supplies:

 Secure power supplies to junction box using 

1/2 in (13 mm)locknuts. Power supplies may be joined together in a wide array 

of configurations. For wet locations use a junction box that is UL Listed for wet 

locations. For dry locations, use any UL Listed junction box.