5
6
To Wall
Flange
To 6 VAC Class 2
Transformer
(Available from Sloan)
Transformer Part Nos.
EL-386 & EL-451
Wiring Diagram
Insert wires into Wire Connectors as
shown. Twist Wire Connectors onto
wires.
120 VAC
6 VAC
SMOOTH
SMOOTH
SMOOTH
One EL-386 Transformer serves one (1) OPTIMA
Closet/Urinal Flushometer. One EL-451
Transformer serves up to eight (8) OPTIMA
Closet/Urinal Flushometers.
Mounting Hole (2)
Center Hole
8
Tighten setscrew against armor
sheath, with 1/8” hex wrench.
Drill two (2) mounting holes into wall and
mount flange using the appropriate
fasteners for the particular wall type.
Mounting Fasteners Provided:
• Plastic Wall Anchor - 1/4” (6 mm) hole
• Hollow Wall Anchor - 5/16” (8 mm) hole
• Toggle Nut Anchor - 1/2” (13 mm) hole
Drill 1/2” (13 mm) center hole. Run Cable
through center hole in Flange.
2