background image

PRIOR TO INSTALLATION

Prior to installing the Sloan EBF-615 or EBF-650 faucet, install the items listed
below. Also, refer to Figures A, B and C.

Lavatory/sink

Drain line

Hot and cold water supply lines or tempered water supply line

IMPORTANT:

ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.

FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

Mixing Valve

When installation includes Sloan’s MIX-25-A or MIX-30-A Mixing Valve, these
instructions AND those included with the Mixing Valve MUST be followed.

TOOLS REQUIRED FOR INSTALLATION

Open end wrenches for the following hex sizes (In.): 1/2, 9/16, 5/8, 11/16, 1

Basin wrench

Phillips head screwdriver, #2

Hammer (if installing plastic or hollow wall anchors to mount control module)

Pliers

1/4" drill bit (if installing plastic wall anchors to mount control module)

5/16" drill bit (if installing hollow wall anchors to mount control module)

3/8" drill bit (if installing toggle nut anchors to mount control module)

INSTALLATION OF EBF-615 OR EBF-650 FAUCET

DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY
INSTALLED. If the batteries are installed before the sensor cable has been
connected to the control module, the faucet will not properly set the
sensing range for the sink on which it has been installed.

The Sloan EBF-615 and EBF-650 battery powered, sensor operated faucets can
be supplied with two back checks. When connecting the faucet to a hot and cold
water supply, two back checks are required as shown in Figure 1. Water
temperature can be controlled by adjusting the supply stops. When connecting
the faucet to a single line water supply or a pre-tempered water supply, a back
check is not required.

Step 1 — Install Back Checks (Option) (Figure 1)

The Sloan Back Check is designed for
installation on a 3/8" Supply Stop. If
an existing Stop is used, the Stop may
require replacement or additional
fittings not  supplied by Sloan for
connection of the Back Checks to the
hot and cold water supply lines.
Supply Stops should be furnished by
the installer.

After flushing the water supply lines
through the Stops, use a compression
nut and compression sleeve to
connect inlet end of Back Check to the
Supply Stop. Tighten Securely.

Note: Failure to install the Back
Checks can  result in a cross flow
connection when the faucet is in the
off position and the supply stops are
open. If the pressures of the hot water
supply  and cold water supply are
different, hot water can migrate into
the cold water supply or cold water
can migrate into the hot water supply.
Most plumbing codes require that the
Back Checks be used to prevent this
occurrence.

Figure 1

SLEEVE

NUT

3/8" COPPER
TUBE

BACK
CHECK

NUT

SLEEVE

SUPPLY STOP WITH 3/8" COMPRESSION

OUTLET (NOT SUPPLIED)

FAUCET SIDE VIEW — Figure C

EBF-615 FAUCET WITH BOTH DUAL AND SINGLE LINE WATER
SUPPLIES

TOTAL LENGTH OF
SENSOR CABLE IS
24" (610 mm)

3-1/2"

(89 mm)

2-1/2"

(64 mm)

2-3/4" (70 mm)

5-1/4"

(133 mm)

3/4" (19 mm)

2" (51 mm)

1-1/4" (32 mm)

12

o

4-1/2"

(114 mm)

3-1/2" (89 mm)

EBF-650 FAUCET WITH BOTH DUAL AND SINGLE LINE WATER
SUPPLIES

TOTAL LENGTH OF
SENSOR CABLE IS
23" (584 mm)

3-1/2"

(89 mm)

2-1/2"

(64 mm)

2-3/4" (70 mm)

5-1/4"

(133 mm)

3/4" (19 mm)

2" (51 mm)

1-1/4" (32 mm)

12

o

4-1/2"

(114 mm)

3-1/2" (89 mm)

IMPORTANT NOTES

DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY INSTALLED. If the batteries are installed before the sensor

cable has been connected to the control module, the faucet will not properly set the sensing range for the sink on which it has been installed.

3

Содержание Optima EBF-615

Страница 1: ...Department at 1 888 SLOAN 14 EBF 650 I I Rev 1 06 00 Code No 0816321 INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED LAVATORY FAUCETS EBF 615 EBF 650 Battery Powered Sensor Operated Lavator...

Страница 2: ...D VALVE BASE GASKET EBF 650 FAUCET WITH SINGLE LINE WATER SUPPLY MODEL EBF 650 A 0 5 gpm 1 9 Lpm Max MODEL EBF 650 B 2 2 gpm 8 3 Lpm Max MODEL EBF 650 C 2 2 gpm 8 3 Lpm Max Laminar Flow EBF 615 FAUCET...

Страница 3: ...supply or a pre tempered water supply a back check is not required Step 1 Install Back Checks Option Figure 1 TheSloanBackCheckisdesignedfor installation on a 3 8 Supply Stop If an existingStopisused...

Страница 4: ...or B All four 4 Cover Screws must be accessible from the chosenmounting position After installation the Cable from Spout to Control Module should have some slack Remove Control Module Cover from Cont...

Страница 5: ...er supply no Back Check is required Install a 3 8 copper Supply Tube between the Supply Stop and the bottom inlet Compression Fitting of Solenoid Valve Refer to Figure A or B Step 7 Install Batteries...

Страница 6: ...ustment is required turn Range Potentiometer counterclockwise to decrease range or clockwise to increase range Cycle Faucet several times to assure that the Sensor range does not inadvertentlypickup r...

Страница 7: ...tting off the water flow The circuit then automatically resets and is ready for the next user CARE AND CLEANING OF CHROME AND SPECIAL FINISHES DO NOT use abrasive or chemical cleaners including chlori...

Страница 8: ...D should flash RED when a user is detected 3 PROBLEM Faucet delivers only a slow flow or dribble when Sensor is activated CAUSE Water supply valve is partially closed SOLUTION Completely open the Supp...

Страница 9: ...ter turn off the water supply at the supply stop s Activate the faucet to relieve any pressure in the system Unscrew the Filter Plug and remove it from the Solenoid Valve Housing Carefully pull the Sc...

Страница 10: ...ssion Sleeves and Screwdriver Not shown 6 EBF 60 A Control Module Assembly includes Base Enclosure Cover Enclosure two 2 Gaskets Solenoid Body Solenoid Enclosure Solenoid Filter Plug and Battery Stop...

Отзывы: