PRIOR TO INSTALLATION
Prior to installing the Sloan EBF-615 or EBF-650 faucet, install the items listed
below. Also, refer to Figures A, B and C.
•
Lavatory/sink
•
Drain line
•
Hot and cold water supply lines or tempered water supply line
IMPORTANT:
•
ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
•
FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
Mixing Valve
When installation includes Sloan’s MIX-25-A or MIX-30-A Mixing Valve, these
instructions AND those included with the Mixing Valve MUST be followed.
TOOLS REQUIRED FOR INSTALLATION
•
Open end wrenches for the following hex sizes (In.): 1/2, 9/16, 5/8, 11/16, 1
•
Basin wrench
•
Phillips head screwdriver, #2
•
Hammer (if installing plastic or hollow wall anchors to mount control module)
•
Pliers
•
1/4" drill bit (if installing plastic wall anchors to mount control module)
•
5/16" drill bit (if installing hollow wall anchors to mount control module)
•
3/8" drill bit (if installing toggle nut anchors to mount control module)
INSTALLATION OF EBF-615 OR EBF-650 FAUCET
DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY
INSTALLED. If the batteries are installed before the sensor cable has been
connected to the control module, the faucet will not properly set the
sensing range for the sink on which it has been installed.
The Sloan EBF-615 and EBF-650 battery powered, sensor operated faucets can
be supplied with two back checks. When connecting the faucet to a hot and cold
water supply, two back checks are required as shown in Figure 1. Water
temperature can be controlled by adjusting the supply stops. When connecting
the faucet to a single line water supply or a pre-tempered water supply, a back
check is not required.
Step 1 — Install Back Checks (Option) (Figure 1)
The Sloan Back Check is designed for
installation on a 3/8" Supply Stop. If
an existing Stop is used, the Stop may
require replacement or additional
fittings not supplied by Sloan for
connection of the Back Checks to the
hot and cold water supply lines.
Supply Stops should be furnished by
the installer.
After flushing the water supply lines
through the Stops, use a compression
nut and compression sleeve to
connect inlet end of Back Check to the
Supply Stop. Tighten Securely.
Note: Failure to install the Back
Checks can result in a cross flow
connection when the faucet is in the
off position and the supply stops are
open. If the pressures of the hot water
supply and cold water supply are
different, hot water can migrate into
the cold water supply or cold water
can migrate into the hot water supply.
Most plumbing codes require that the
Back Checks be used to prevent this
occurrence.
Figure 1
SLEEVE
NUT
3/8" COPPER
TUBE
BACK
CHECK
NUT
SLEEVE
SUPPLY STOP WITH 3/8" COMPRESSION
OUTLET (NOT SUPPLIED)
FAUCET SIDE VIEW — Figure C
EBF-615 FAUCET WITH BOTH DUAL AND SINGLE LINE WATER
SUPPLIES
TOTAL LENGTH OF
SENSOR CABLE IS
24" (610 mm)
3-1/2"
(89 mm)
2-1/2"
(64 mm)
2-3/4" (70 mm)
5-1/4"
(133 mm)
3/4" (19 mm)
2" (51 mm)
1-1/4" (32 mm)
12
o
4-1/2"
(114 mm)
3-1/2" (89 mm)
EBF-650 FAUCET WITH BOTH DUAL AND SINGLE LINE WATER
SUPPLIES
TOTAL LENGTH OF
SENSOR CABLE IS
23" (584 mm)
3-1/2"
(89 mm)
2-1/2"
(64 mm)
2-3/4" (70 mm)
5-1/4"
(133 mm)
3/4" (19 mm)
2" (51 mm)
1-1/4" (32 mm)
12
o
4-1/2"
(114 mm)
3-1/2" (89 mm)
IMPORTANT NOTES
DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY INSTALLED. If the batteries are installed before the sensor
cable has been connected to the control module, the faucet will not properly set the sensing range for the sink on which it has been installed.