Step 5 — Install Anchoring Hardware (Figure 7)
Carefully remove the Sink from the wall and place in a safe location.
Drill a 1" (25 mm) diameter hole into the wall at each of the four (4) locations marked
in Step 4. Refer to Figure 1 Rough-in Diagrams for further details on mounting hole
positioning. (Mounting height can vary to meet individual installation requirements.)
Install the four (4) Anchors for Sink as instructed in the Anchor Manufacturer’s
Installation Instructions.
Step 6 — Mount Scrub Sink to Wall (Figure 8)
With the help of an assistant, carefully lift and hang the Scrub Sink onto the Z-clips.
Position Sink so that the four (4) Sink mounting holes are aligned with the wall
anchors located in the wall.
Install and tighten the four (4) Anchoring Fasteners securely.
Step 7 — Install Drain (Figure 9)
Install Drain Line and “P” Trap (furnished by installer) as instructed in the
Manufacturer’s Installation Instructions.
Step 8 — Connect Water Supply Lines (Figure 10)
Note: If installation includes a MIX-110-A or MIX-70-A Mixing Valve, install mixing
valve before connecting the water supply lines. Refer to the Installation Instructions
supplied with the Sloan mixing valve.
Important: Before connecting water supply lines to Supply Stops, flush all water lines
until water is clear.
Connect hot and cold water supply lines to Supply Stops. (Supply Stops have a 1/2"
male pipe thread inlet.) Open Supply Stops completely.
Note: If sink is ordered without a mixing valve, a single pretempered water supply line
must be installed.
Step 9 — Connect Transformer (Figures 11 and 12)
Important: DO NOT plug Transformer into receptacle until all wiring has been
completed.
The Transformer is designed to be plugged into a 120 VAC Ground Fault Interrupt
(GFCI) wall receptacle. It is supplied with a 10 foot Cable; however, this Cable can
and should be shortened to meet installation requirements.
Separate and strip one end of Transformer Power Cable approximately 3/16 to 1/4
inch (5 to 6 mm). Install Transformer Strain Relief 3 inches (76 mm) from stripped
end of Power Cable. Squeeze Strain Relief with a pliers and insert stripped end of
Power Cable and Strain Relief into 3/8 inch (10 mm) hole in Control Module as
shown in Figure 12.
Important: Twist stranded ends of Power Cable before inserting into Terminal Block.
Fraying of Stranded Power Cable Wire can cause a short and damage the Control
Module and Transformer when power is supplied.
Connect Power Cable to Terminal Block on Connector Board. Refer to Figure 13 for
location of 24 Volt Terminal Block on Connector Board.
Install Crimp Connectors to opposite end of Transformer Power Cable and connect
Power Cable ends to Transformer Terminals as shown in Figure 14.
Step 10 — Plug Transformer into Receptacle (Figure 15)
Make sure that power is supplied to the receptacle(s). Plug the Transformer into the
lower receptacle. For double and triple station sinks, plug the remaining Transformers
into the remaining receptacles.
Important: Plug-in Transformer MUST be used with a Ground Fault Interrupt (GFCI)
Receptacle to help prevent possible electrical shock.
6
INSTALL ANCHORS
(4 REQUIRED)
Figure 7
INSTALL SINK
MOUNTING
FASTENERS
(2 FASTENERS ON
EACH SIDE OF SINK)
Figure 8
INSTALL DRAIN LINE
AND “P” TRAP
2000 SERIES
SCRUB SINK
SHOWN
Figure 9
CONNECT HOT AND COLD
WATER SUPPLY LINES TO
SUPPLY STOPS
SUPPLY STOP
Figure 10
PLUG-IN TRANSFORMER
(ETF-233 SHOWN)
Figure 11
TRANSFORMER
STRAIN RELIEF
3/8" (10 mm) HOLE
Figure 12
CONTROL MODULE
24 VOLT TERMINAL
BLOCK
Figure 13
RECEPTACLES ARE INTERCHANGEABLE
(CONNECTORS CAN BE INSERTED INTO ANY RECEPTACLE)
RED LIGHT INDICATES
SENSOR IS ACTIVATED
GREEN LIGHT INDICATES
POWER TO BOARD
TRANSFORMER TERMINALS
CRIMP CONNECTORS
TRANSFORMER
POWER CABLE
PLUG-IN TRANSFORMER
(ETF-233 SHOWN)
Figure 14