Repair Parts and Maintenance Guide
143
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
Wait, until LED flashes GREEN.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
BASYS
®
Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and
should not require resetting unless under extreme situations: high
reflection or low light.
IR Activation (see previous page).To enter programming mode place finger
on IR clic for 2 times then remove. Light on side of crown should blink to
indicate programming mode.
SENSOR RANGE ADJUSTMENT
BATTERY REPLACEMENT
NOTE: Replace battery when LED1 indicator flashes RED each time
faucet is in use or when faucet stops functioning. LED1 is identified
by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening 2 hex screws located on
underside of spout and slide crown down and lift off.
NOTE: Screw is captive within faucet body and will
NOT fall out.
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
Cover IR clic until LED flashes RED 4 times - hold IR clic on until LED
flashes 1 time to 8 times from minimum to maximum range. See diagram
below. Release when requested range is reached.
Remove red cover over the battery. Remove battery holder from the faucet
body. Replace battery in the holder. Holder drops into the faucet body.
Place the red cover over the battery.
Slide on crown and secure in 2 places.