Sloan EAF-3X0 Series Скачать руководство пользователя страница 6

6

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

After inserting the new battery and opening the supply stops, wait 15 seconds, remove and then reinsert the battery.

A

C

B

C

D

IR activation (see page 5). To enter programming 

mode place finger on IR-Click (covering bottom 

half of sensor) 1 time for 2 seconds and remove, 

ORANGE light will come on. Then, place finger 2 

times then remove. Light on sensor should blink 

RED to indicate programming mode. 

Wait until 

LED flashes 

ORANGE

A

Cover IR-Click (bottom half of 

sensor) until LED flashes RED 4 

times - hold IR-Click until LED 

flashes 1 to 8 times from minimum 

to maximum range. See diagram 

below. Release when requested 

range is reached.

B

D

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

4 Sec.

1x 2 Sec.

auto

OFF

10 Sec.

Deactivate

...1x

Activate 12HR

...2x

Activate 24HR

Activate 48HR

...3x

...4x

touch

touch

touch

touch

touch

(bottom half)

1x

2x

3x

4x

5x

7x

8x

6x = factory setting

SENSOR RANGE ADJUSTMENT DIAGRAM

 

SENSOR RANGE ADJUSTMENT

12/24 LINE PURGE FEATURE

This feature will operate the faucet every 12 or 24 hours since 

last use, or if not used, to prevent stagnant water conditions.
Default purge duration is two minutes.
Consult factory regarding other timing options.

Steps to activate purge line feature:

1. Activate IR: cover lower part of sensor window with a white 

card/paper until LED flashes ORANGE to confirm program 

mode is active.

2. Cover lower part of sensor window once more with a white 

card/paper for approximately 24 seconds (ignore LED 

indications during this period). Release when requested 

program is reached. (See LED indications to right.)

Содержание EAF-3X0 Series

Страница 1: ...ce no later than 30 days after your purchase date In case of a conflict with this summary the terms and conditions set forth in the complete Limited Warranty will prevail pose of resale This warranty does not cover the life of batteries THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY ...

Страница 2: ...de View Side View Front View Ø 2 1 8 54 mm 33 5 mm Ø 1 5 16 33 5 mm Min Hole Required 4 3 64 103 mm Spout O ring 13 49 64 350 mm 9 16 UNEF 13 330 mm Long Flex Hose If a connection to separate hot and cold water supplies is desired then a Bak Chek tee fitting or BDM or BDT not supplied must be used prior to connecting to the faucet Tempered Supply Nut Retainer Gasket 45 mm 1 45 mm Max Deck Thicknes...

Страница 3: ...ely to the supply stop s A C B Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector IMPORTANT Flush dirt debris and sediment from supply line s before connecting flex hose s Note If water flows immediately upon opening supply stops the solenoid is in the open position and will be cycled to the closed position ...

Страница 4: ...t Faucet will run for four 4 seconds and the range will automatically adjust to its environment Wait ten 10 seconds after water shuts off before using faucet Activate Faucet and check for leaks If faucet does not function refer to the Troubleshooting section of this instruction manual Optional To fix temperature set lever to the desired position then remove lever and plug hole with cap A A A B B 6...

Страница 5: ...ick cover bottom half of sensor with finger wait 2 seconds for Orange light then remove finger When in programming mode each touch of IR Click will produce a quick Orange flash 10 Sec 10 Sec 10 Sec 10 Sec 10 Sec Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector A30 A10 A20 A30 A10 A20 Function Press Button LED Signal Temporary OFF 2 min 1 1 time for 2 seconds 2 2 times double ...

Страница 6: ...10 Sec 4 Sec auto OFF 10 Sec 4 Sec auto OFF 10 Sec 4 Sec 1x 2 Sec auto OFF 10 Sec Deactivate 1x Activate 12HR 2x Activate 24HR Activate 48HR 3x 4x touch touch touch touch touch bottom half 1x 2x 3x 4x 5x 7x 8x 6x factory setting SENSOR RANGE ADJUSTMENT DIAGRAM SENSOR RANGE ADJUSTMENT 12 24 LINE PURGE FEATURE This feature will operate the faucet every 12 or 24 hours since last use or if not used to...

Страница 7: ... Open water supply stop s Cause Water supply stop strainer s clogged Solution Turn off water at supply stop s Remove clean and reinstall water supply stop strainer s Replace strainer s if required Turn on water at supply stop s Indicator Solenoid valve does not produces an audible click Cause Battery low Solution Replace battery refer to battery replacement Solution Contact Sloan Technical Support...

Страница 8: ...ray Head 5A EAF 1021 A Electronic Sensor 15 Second Shut off with Fixing Clip Kit 0 5 gpm only 5B EAF 1018 A Electronic Sensor 7 Second Shut off with Fixing Clip Kit 1 5 gpm only 6 EAF 1019 A Mixer Handle Assembly and Cartridge Kit 7 EAF 2 Solenoid Valve Cartridge IQ Faucet 8 EAF 1020 A Integral Side Mixer Handle Kit 9 EAF 8 Back Check 2 required for ISM models 10 EAF 1 Faucet Mounting Kit 11 EAF 1...

Отзывы: