INSTALLATION INSTRUCTIONS FOR EAF-3X0 SERIES ELECTRONIC, 

SENSOR-ACTIVATED LAVATORY FAUCETS

Code No: 0816654

Rev. 5 (07/22)

Faucet Variations

-

ISM

 

Integral Spout Temperature      

             Mixer

SLOAN

®

 LIMITED WARRANTY SUMMARY

Sloan Valve Company (“Sloan”), warrants its products against defects in materials and workmanship, excluding damage 

caused by matters beyond Sloan’s reasonable control.  Instructions for filing claims can be found in the Limited Warranty which 

can be obtained at 

www.Sloan.com

 or by requesting a free copy by telephone at 888.756.2614.  Sloan will repair or replace 

your defective product, or provide a refund, as your exclusive remedy.  This is only a general summary of Sloan’s Limited War-

ranty so it is important to note that the specific terms, conditions, limitations and exclusions, including the duration of warranty 

coverage for your particular Sloan product, are contained in the actual Sloan Limited Warranty.  The Limited Warranty is subject 

to applicable laws in your country, state, province or other jurisdiction—and disputes arising under the Limited Warranty are to 

be resolved by binding arbitration unless you provide Sloan with an opt-out notice no later than 30 days after your purchase 

date.  In case of a conflict with this summary, the terms and conditions set forth in the complete Limited Warranty will prevail.

pose of resale. This warranty does not cover the life of batteries.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY 
CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

Prior to installing the Sloan OPTIMA Plus® EAF-3X0 Series 

faucets, install the items listed below. Also, refer to rough-in 

illustrations.

•  Lavatory/sink

•  Drain line

•  Hot/Cold water supply lines or pre-tempered water supply 

line
IMPORTANT:

•  ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE 

WITH APPLICABLE CODES AND REGULATIONS.

•  FLUSH ALL WATER LINES PRIOR TO MAKING 

CONNECTIONS.

•  KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO 

PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY 

SEALANT ON COMPRESSION FITTINGS.

Trim Plates

When the EAF faucet is installed on a sink that has three (3) 

hole punchings, a trim plate should be used. 

Trim plates must be 

specified and ordered separately.

ETF-312-A    Trim Plate for 4” (102 mm) Centerset Sink

ETF-510-A    Trim Plate for 8” (203 mm) Centerset Sink

Tools Required for Installation

•  13mm open wrench or nut driver for faucet retainer nut

•  3/4” open end wrench for female end of flex hose

EAF-3X0

EAF-3X0-ISM

Содержание EAF-3X0 Series

Страница 1: ...ce no later than 30 days after your purchase date In case of a conflict with this summary the terms and conditions set forth in the complete Limited Warranty will prevail pose of resale This warranty does not cover the life of batteries THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY ...

Страница 2: ...de View Side View Front View Ø 2 1 8 54 mm 33 5 mm Ø 1 5 16 33 5 mm Min Hole Required 4 3 64 103 mm Spout O ring 13 49 64 350 mm 9 16 UNEF 13 330 mm Long Flex Hose If a connection to separate hot and cold water supplies is desired then a Bak Chek tee fitting or BDM or BDT not supplied must be used prior to connecting to the faucet Tempered Supply Nut Retainer Gasket 45 mm 1 45 mm Max Deck Thicknes...

Страница 3: ...ely to the supply stop s A C B Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector IMPORTANT Flush dirt debris and sediment from supply line s before connecting flex hose s Note If water flows immediately upon opening supply stops the solenoid is in the open position and will be cycled to the closed position ...

Страница 4: ...t Faucet will run for four 4 seconds and the range will automatically adjust to its environment Wait ten 10 seconds after water shuts off before using faucet Activate Faucet and check for leaks If faucet does not function refer to the Troubleshooting section of this instruction manual Optional To fix temperature set lever to the desired position then remove lever and plug hole with cap A A A B B 6...

Страница 5: ...ick cover bottom half of sensor with finger wait 2 seconds for Orange light then remove finger When in programming mode each touch of IR Click will produce a quick Orange flash 10 Sec 10 Sec 10 Sec 10 Sec 10 Sec Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector A30 A10 A20 A30 A10 A20 Function Press Button LED Signal Temporary OFF 2 min 1 1 time for 2 seconds 2 2 times double ...

Страница 6: ...10 Sec 4 Sec auto OFF 10 Sec 4 Sec auto OFF 10 Sec 4 Sec 1x 2 Sec auto OFF 10 Sec Deactivate 1x Activate 12HR 2x Activate 24HR Activate 48HR 3x 4x touch touch touch touch touch bottom half 1x 2x 3x 4x 5x 7x 8x 6x factory setting SENSOR RANGE ADJUSTMENT DIAGRAM SENSOR RANGE ADJUSTMENT 12 24 LINE PURGE FEATURE This feature will operate the faucet every 12 or 24 hours since last use or if not used to...

Страница 7: ... Open water supply stop s Cause Water supply stop strainer s clogged Solution Turn off water at supply stop s Remove clean and reinstall water supply stop strainer s Replace strainer s if required Turn on water at supply stop s Indicator Solenoid valve does not produces an audible click Cause Battery low Solution Replace battery refer to battery replacement Solution Contact Sloan Technical Support...

Страница 8: ...ray Head 5A EAF 1021 A Electronic Sensor 15 Second Shut off with Fixing Clip Kit 0 5 gpm only 5B EAF 1018 A Electronic Sensor 7 Second Shut off with Fixing Clip Kit 1 5 gpm only 6 EAF 1019 A Mixer Handle Assembly and Cartridge Kit 7 EAF 2 Solenoid Valve Cartridge IQ Faucet 8 EAF 1020 A Integral Side Mixer Handle Kit 9 EAF 8 Back Check 2 required for ISM models 10 EAF 1 Faucet Mounting Kit 11 EAF 1...