1. Wiring diagram

Equpment  configuration  consists  of  several  steps:  basic  network  settings,  logical  address  setting  and  server  IP  address 
setting  for  calls  redirection.  Indoor  monitor  or  outdoor  panel  parameters  can  be  changed  through  the  Slinex  IP Tool 
software. Connection schematic diagram described below: 

Note:

 

* Calls redirection server  IP address has been taken from the local network: 192.168.1.134, this address must be the 

same for all devices inside the system.

 

** Logical address of the door panel and internal monitor for the current building and entrance must have the same 

parameters.

2. Indoor monitor  configuration

     2.1. Network settings 

Network settings configuration can be changed on the next bookmark: File 

→ 

Normal Attribute.  

For example, following parameters were applied for the monitor network settings:      

Note:

            * Following settings can be applied through the monitor interface: date, time, passwords, network settings and the logical  

address setting.

                  ** Before monitor will be connected to the local network make sure that computer have the same subnet mask with the monitor. 

The default network settings are: IP Address: 192.168.14.252; subnet Mask: 255.255.0.0; gateway number: 192.168.14.254;

{ Design. Uniqueness. Innovations }

     

Q

UICK INSTALLATION GUIDE

IP Address:     192.168.1.10
Logical address: 01010001

IP Address:     192.168.1.11
Logical address:    01 01 00

Logical address consists of: 
Block – Building: 01; (up to 2 digits max);
Unit – Entrance: 01; (up to 2 digits max;
Floor Number – Floor: 00; (up to 2 digits max);
Room Number – Room: 01; (up to 2 digits max) ;

Following logical address of the monitor was seted as an example: 0101 00 01;

      2.3. Call redirection server settings

Call redirection server settings can be changed on the next bookmark:  File 

→ 

Advance  Attribute.  

Following call redirection server settings wwere seted as an example:

     2.2. Logical address settings

Logical address settings configuration can be changed on the next bookmark:

 File 

→ 

Advance  Attribute 

 Parameter Setting.

   

 IP address of the server must be the same for all devices inside one system.

UPS

Outdoor panel

Router

Individual panel

Indoor monitor

Power supply