1. Wiring diagram
Equpment configuration consists of several steps: basic network settings, logical address setting and server IP address
setting for calls redirection. Indoor monitor or outdoor panel parameters can be changed through the Slinex IP Tool
software. Connection schematic diagram described below:
Note:
* Calls redirection server IP address has been taken from the local network: 192.168.1.134, this address must be the
same for all devices inside the system.
** Logical address of the door panel and internal monitor for the current building and entrance must have the same
parameters.
2. Indoor monitor configuration
2.1. Network settings
Network settings configuration can be changed on the next bookmark: File
→
Normal Attribute.
For example, following parameters were applied for the monitor network settings:
Note:
* Following settings can be applied through the monitor interface: date, time, passwords, network settings and the logical
address setting.
** Before monitor will be connected to the local network make sure that computer have the same subnet mask with the monitor.
The default network settings are: IP Address: 192.168.14.252; subnet Mask: 255.255.0.0; gateway number: 192.168.14.254;
{ Design. Uniqueness. Innovations }
Q
UICK INSTALLATION GUIDE
IP Address: 192.168.1.10
Logical address: 01010001
IP Address: 192.168.1.11
Logical address: 01 01 00
Logical address consists of:
Block – Building: 01; (up to 2 digits max);
Unit – Entrance: 01; (up to 2 digits max;
Floor Number – Floor: 00; (up to 2 digits max);
Room Number – Room: 01; (up to 2 digits max) ;
Following logical address of the monitor was seted as an example: 0101 00 01;
2.3. Call redirection server settings
Call redirection server settings can be changed on the next bookmark: File
→
Advance Attribute.
Following call redirection server settings wwere seted as an example:
2.2. Logical address settings
Logical address settings configuration can be changed on the next bookmark:
File
→
Advance Attribute
→
Parameter Setting.
IP address of the server must be the same for all devices inside one system.
UPS
Outdoor panel
Router
Individual panel
Indoor monitor
Power supply