9
5916
11
2022
-
SEP & SEP IP user manual
MG_0088
KEY:
1. Electro motor
2. Directional Solenoids/ power & control cables
3. Coupling (inside motor bracket
4. Motor Bracket
5. Gear Leg
6. Propeller
7. Anode
8. Propeller Drive pin
9. Washer
10. Lock Nut
11. Fastening Screw for anode
SE / SEP (IP)
*30
*40
SE / SEP (IP)
*50
SE / SEP (IP)
*60
SE / SEP (IP)
*80
*100
*120
*130
*170
11
11
11
11
10
10
10
10
8
8
8
9
9
9
9
7
7
7
7
7
7
6
6
6
6
6
6
6
6
5
5
5
5
5
5
5
5
4
4
4
4
3
3
3
3
2
2
2
1
1
1
1
MC_0352
Advanced Control Panel Troubleshooting
Control panels operating on the S-link system display all faults via the control panel interface or via other warming methods.
To review any issues of your product refer to the appropriate user manual for a complete list of fault codes and troubleshooting guides.
For additional supporting documentation, we advise you to visit
our website
www.sleipnergroup.com
MC_0013
Basic Troubleshooting
*
Not applicable to SX thrusters.
Before seeking assistance from the website help desk from your Sleipner dealer/ distributor, please perform these tests.
(NB: If you are unable to understand or perform these checks, you must consult a Sleipner distributor.)
CHECK
SOLUTION
The motor runs, but there is no thrust
Check propellers are fi tted, fastened correctly and there
is no damage to the prop shaft.
Re-fasten or replace if necessary
*
Check the flexible coupling between the motor and
drive shaft is fi tted correctly and not damaged.
Replace if necessary
*
Check the gear leg is not damaged.
Replace if necessary
The thrusters performance is reduced
Check the propeller, gear house and tunnel are free from
growth/ barnacles or debris and damage.
Remove growth and clean.
(NB: If there is obstruction in the tunnel it will disturb/ block
the water flow and signifi cantly reduce performance.)
Check the battery is in a good working condition.
(NB: Keep the main engine(s) running in use to have a continuous charge to the
batteries)
• Check batteries are not worn out or in a bad charged condition
• Check electrical connections/ wiring for damage or wear (corrosion)
• Check cables are the correct size per the product manual
• Tighten/ re-adjust connections
The thruster does not start/ works in only one direction or does not turn off
Check the main switch is active/ on.
Open the main switch if it is closed.
Check all battery fuses are in good condition.
• Check batteries
• Check electrical connections/ wiring for damage or wear (corrosion)
• Tighten/ re-adjust and clean connections
The thruster is not shutting off after the Joy Stick/ panel
is disengaged.
Hit the main switch to disengage the thruster. Contact and consult a Sleipner distributor
as the control system has been damaged.
The thruster works in only one direction
Damaged relay.
Hit the main switch to disengage the thruster. Contact and consult a Sleipner distributor
as the control system has been damaged.
The thruster runs in a pulsing action
This is a build-in error response.
-Solenoids failure
Hit the main switch to disengage the thruster. Contact and consult a Sleipner distributor.
The solenoid might be in a lock-in/ auto stop position.
Hit the main switch to disengage the thruster. Contact and consult a Sleipner distributor.
Replace if