SLEIPNER MOTOR AS SIDE-POWER SEP Series Скачать руководство пользователя страница 3

 3

5916

9

2020

-

SEP & SEP IP user manual

DECLARATION OF CONFORMITY

Sleipner Motor AS

P.O. Box 519, Arne Svendsensgt. 6-8

N-1612 Fredrikstad, Norway 

Declare that this product with accompanying standard control systems complies with 

the essential health and safety requirements according to:

DIRECTIVE 2013/53/EU

DIRECTIVE 2014/30/EU

DIRECTIVE 2014/35/EU

MC_0020

MC_0004

Important Thruster User Considerations and Precautions

EN

•  Ensure you know the location of the main battery switch that disconnects the thruster from all power sources (batteries) so the thruster can    

  be turned off  in case of serious malfunction.

•  Always turn the control device off  when the thruster is not in use or when leaving the boat.

•  When leaving the boat always turn off  the main power switch for the thruster.

•  The maximum continuous run time of the electrical thruster is approximately 3 minutes. The motor is equipped with a built-in thermal cut-off  switch that    

   will shut the motor off  when overheating. Consider this when planning your manoeuvring.

•  Never use thrusters out of water.

•  If the thruster stops giving thrust while running, there is possibly a problem in the drive system. You must immediately stop running the thruster and  

   turn it off . Running the thruster for more than a few seconds without resistance from the propeller can cause serious damage to the thruster.

•  We advise keeping the main engine(s) running while using the thruster. This will keep the batteries in a good charge condition. It will also give better  

  performance to the thruster.

•  If the performance of the thruster is reduced check the battery system or check the tunnel for marine growth. 

•  If two panels are operated with confl icting directions at the same time the thruster will not run. If both are operated in the same direction, the thruster  

   will run in this direction.

•  If you notice any faults with the thruster switch it off  to avoid further damage.

•  The electro motor, its components, contacts/ plugs or other joints in the control cables must be mounted so they will remain dry at all times.

•  It is the owner/ captain/ other responsible parties full responsibility to assess the risk of any unexpected incidents on the vessel. If the thruster stops  

  giving thrust for some reason while manoeuvring you must have considered a plan on how to avoid damage to persons or other objects.

 

•  The primary purpose of the thruster is to manoeuvre/ dock the vessel. Forward/ reverse speed must not exceed 4 knots when operated.

IMPORTANT 

Failure to follow the Considerations and precautions can cause serious injury / damage and will render all warranty given 

by Sleipner Motor AS VOID.

Never use thrusters when close to objects/ persons or pets in the water. The thruster will draw objects into the tunnel and 

the rotating propellers. This will cause serious injuries and damage the thruster.

Always turn the main power switch off  before touching any part of the thruster, An incidental start while touching moving 

parts can cause serious injuries.

Never store items (e.g. equipment, sails, ropes etc.) in the same compartment as the thruster. When the thruster runs for an 

extended period, it can reach 150°C and will cause damage to nearby items or cause a fi re. The electromotor will generate 

some carbon dust so any storage compartment must be separated from the thruster to prevent nearby items from becoming 

dusty/ dirty.

 

Any loose items near the thruster motor can cause problems with electrical wiring coming loose and short-circuiting.

MC_0007

User Considerations and Precautions for IP

EN

IMPORTANT 

NEVER Disassemble any part of the Ignition Protected assembly. Tampering with the Ignition Protected assembly will 

cause it to lose this safety feature.

If there is a problem with your Ignition Protected stern thruster, please contact your dealer.

Содержание SIDE-POWER SEP Series

Страница 1: ...TOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com Document id Revision Date 5916 9 DC SEP SEP IP SERIES OPERATIONAL THRUSTER USER MANUAL To download your language go to www side power co...

Страница 2: ...24V SEP80 185T 12V SEP80 Tunnel thruster 12V SEP80 185T 24V SEP80 Tunnel thruster 24V SEP60 185S 12V SEP60 Tunnel thruster 12V SEP60 185S 24V SEP60 Tunnel thruster 24v SEP60 185S2 12V SEP60 Tunnel th...

Страница 3: ...other joints in the control cables must be mounted so they will remain dry at all times It is the owner captain other responsible parties full responsibility to assess the risk of any unexpected incid...

Страница 4: ...h a red STOP button for an emergency stop function Joystick Control To Turn the bow in the desired direction move the joystick in the direction you wish the bow to move Button Control For HOLD functio...

Страница 5: ...joystick for stern thruster Control panel example Control panel example Control panel example Control panel example Activating the stern thruster Activating both bow and stern thruster to rotate the b...

Страница 6: ...ar leg from marine growth Paint the propeller and gear leg with anti fouling before every season to keep it clean from sea growth NB Never paint the anode sealing or propeller shaft Ensure paint does...

Страница 7: ...motor bracket 4 Motor Bracket 5 Gear Leg 6 Propeller 7 Anode 8 Propeller Drive pin 9 Washer 10 Lock Nut 11 Fastening Screw for anode SE SEP 50 SE SEP 60 SE SEP 80 100 120 130 150 170 210 SE SEP 250 3...

Страница 8: ...nside motor bracket 4 Motor Bracket 5 Gear Leg 6 Propeller 7 Anode 8 Propeller Drive pin 9 Washer 10 Lock Nut 11 Fastening Screw for anode SE SEP IP 30 40 SE SEP IP 50 SE SEP IP 60 SE SEP IP 80 100 12...

Страница 9: ...o check you must consult a Side Power distributor Control panels operating on the S link system display all faults via the control panel interface or via other warming methods To review any issues of...

Страница 10: ...are fastened securely The area around the thruster is clean and dry If there are signs of water try to nd the source and eliminate it Apply the propeller and gear leg with anti fouling Batteries are i...

Страница 11: ...peration Manual have been complied with and that the defect remains e warranty service shall be performed only by the Warrantor or an authorized Service Centre and any attempt to remedy the defect by...

Страница 12: ...cument was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the produc...

Отзывы: