SLEIPNER MOTOR AS SIDE-POWER PJC-322 Скачать руководство пользователя страница 4

4

PJC-212

     

1.0.0- 2010

MENU SYSTEM:

Access menu system by pressing menu button

EMERGENCY STOP:

When the STOP button is pressed, the hydraulic dump valve will activate and the 

thrusters will stop. On systems with two oil tanks, dump valves on both tanks will 

activate and all thrusters will stop.

The EMERGENCY STOP ACTIVATED sybol will be shown on the display. In addition red 

LEDs on both sides of the panel will blink and the external buzzer is activated.

NB: FOR EMERGENCY STOP ONLY!

Press STOP again to reactivate the hydraulic system.

The external buzzer can be muted by pressing the button under the loud-

speaker symbol.

SETTINGS

The menu system contains of 5 settings:

 1 - Cooling Pump

 2 - Pump Settings

 3 - Language

 4 - Display Settings

 5 - Automatic OFF time

Select settings

Ends settings

Chooses function

1/5 Cooling Pump

The cooling pump can be set to “always ON” or “Automatic”.

When the option “Automatic” is selected, the cooling pump will start when oil tem-

perature exceeds 50oC and stop when the oil temperature goes below 40oC.

On systems with two oil tanks, this setting will apply to both tanks.

2/5 Pump Settings

Use 

to choose between Pump 1 or Pump 2 and select by pressing 

When a pump is choosen, switch between available settings with        . 

Use     to save settings.

PUMP 1 (PTO-mounted): Pump can only be set to OFF or ON

PUMP 2 (PTO-mounted): Pump can be set to ON or AUTO

When pump 2 is set to AUTO and an SPS stabilizer is active, the pump will start 

when oil pressure goes below 80 Bar and run for 15 minutes or when a thruster is 

running.

When an SPS Stabilizer is not active, Pump 2 will always run. AUTO is used when 

the SPS stabilizer is installed to save fuel/energy while the stabilizer system is run-

ning. On systems with two oil tanks, the settings will apply for both tanks.

NB: “Pump 2: AUTO” must only be used on PHC 024 with firmware v.1.008 

or newer!

Содержание SIDE-POWER PJC-322

Страница 1: ...N Installasjons og brukermanual Made in Norway Sleipner Motor AS 2010 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 w w w s i d e p o w e r c o m sidepo...

Страница 2: ...re pressure Interactive multi language menus CAN Bus communication with thrusters and accessories Plug play cables waterproof and compact connectors Diagnostics via panel Connector for external buzzer...

Страница 3: ...vated The alarm will be reset automatically when temperature goes below 65oC The thrusters can be run when the oil alarms are active COMMUNICATION ERROR If there is a communication error between the p...

Страница 4: ...oling pump can be set to always ON or Automatic When the option Automatic is selected the cooling pump will start when oil tem perature exceeds 50oC and stop when the oil temperature goes below 40oC O...

Страница 5: ...backlight Use to switch between daytime or night settings End setting by pressing Adjustments will automatically end after 3 seconds of inactivity 5 5 Automatic OFF time Set time from last activity t...

Страница 6: ...ed while this display is shown Exit Service Menu by pressing SERVICE MENU Systems with two oil tanks Shows oil pressure and temperature in both hydraulic tanks as well as the serial number of the pane...

Страница 7: ...7 PJC 212 1 0 0 2010 Measurements...

Страница 8: ...215 www imnasa com imnasa imnasa com Sweden Sleipner AB Str mstad Tel 46 526 629 50 Fax 46 526 152 95 www sleipnerab se Switzerland Marine Parts Technics AG Volketswil Tel 41 1 997 40 90 Fax 41 1 997...

Отзывы: