OVERSPEED GOVERNOR     SLC-LF 18 CD 

 

GENERAL ASSEMBLY INSTRUCTIONS LF 18 CD 

MM.LF18CD.00E 

Revision 1 

2011-06-16 

Pag. 3/4 

 
 
 

 

ELECTRICAL CONTROL 

OVERSPEED SWITCH 

 

 
Connect  the  safety  line  to  the  normally  closed 

switches and the reset solenoid of the remote system of reset 
according to the solenoid characteristics. 
 
 

Turn  manually  the  lever  of  the  switch  verifying  the 

opening  of  the  safety  line  across  the  switch.  Then,  feed  the 
solenoid  to  reset  the  switch  checking  the  switch  wheel  is 
placed in the housing of the system 

 

 

Check that the system is not going to interfere with the 

chassis in the movement of the actuator disk of the governor during the wedging of 
the  safety  gears  for  what  a  free  zone  will  have  to  exist  around  the  system  of 
approximately about ±11º. 

 

 

If necessary, you may replace the solenoid 

and  the  electrical  contact  without  the  unsealing  of 
the  kit.    To  that  end,  the  anchoring  screws  of  the  switch  and/or  the  solenoid 
should  loosen,  replace  by  other  elements  of  identical  characteristics  and  fix  the 
replaced  elements  with  the  anchoring  screws.  Do  not  unsealing  of  anchoring 
screws  of  the  kit  because  it  can  influence  the  speeds  of  performance  of  the 
system. If necessary,  you  should get in touch with SLC to report on the process 
to follow. 

 

 

 

TRIPPING SWITCH 

If  it  is  a  governor  with  tripping  switch,  connect  it  at  normally  close  and  check  if  it 

open and close  the contact mooving  the  governor disk. All test should be done  with the 
elevator stopped. 

 