ELECTRICAL CONTROL
OVERSPEED SWITCH
Connect the safety line to the normally closed
switches and the reset solenoid of the remote system of reset
according to the solenoid characteristics.
Turn manually the lever of the switch verifying the
opening of the safety line across the switch. Then, feed the
solenoid to reset the switch checking the switch wheel is
placed in the housing of the system
Check that the system is not going to interfere with the
chassis in the movement of the actuator disk of the governor during the wedging of
the safety gears for what a free zone will have to exist around the system of
approximately about ±11º.
If necessary, you may replace the solenoid
and the electrical contact without the unsealing of
the kit. To that end, the anchoring screws of the switch and/or the solenoid
should loosen, replace by other elements of identical characteristics and fix the
replaced elements with the anchoring screws. Do not unsealing of anchoring
screws of the kit because it can influence the speeds of performance of the
system. If necessary, you should get in touch with SLC to report on the process
to follow.
TRIPPING SWITCH
If it is a governor with tripping switch, connect it at normally close and check if it
open and close the contact mooving the governor disk. All test should be done with the
elevator stopped.