V
ICTORY VSPH Models
9
9 IN. MAX.
V
6 IN. MIN.
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
TO DRAIN OR
CONTAINER
OUTSIDE VENT TERMINATION
ELBOW WITH SCREEN
OUTSIDE
WALL
STANDARD 90? ELBOW
OR
TIGHT RADIUS 90? ELBOW
12" MIN
SNOW LINE
(SEE DEFINITION)
V
VSPH/NDV BOILER
DRAIN & TRAP
CONDENSATION
BUILT-IN
WITH WATER
FILL TRAP
W
AIR INTAKE
(DO NOT BLOCK)
STANDARD 90?
ELBOW
3 IN. DIA.
S
3 IN. DIA.
S.S.FLUE
PIPE (SEE
PAGE 5)
3
A U/L LISTED WALL THIMBLE
MUST BE USED ON COMBUSTIBLE
WALLS. S/F P/N 440695
(ADJUSTABLE 5 IN. TO 8 IN.)
MAY BE USED. ABOVE THIMBLE
MUST BE USED WITH HEAT-FAB
SLIP JOINT CONNECTOR
A WAL
PRESS./TEMP.
GAUGE
VICTORY VSPH/NDV MODELS, SIDEWALL VENTING
All joints must be liquid and pressure tight. Use U/L listed single wall 3" dia.
AL29-4C S.S.*. venting materials (See page 5).
Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated snowfalls accumulate to.
The height should be used as the SNOW LINE.
*
AL 29-4C IS A REGISTERED TRADEMARK OF ALLEGHENY LUDLUM CORP
.
Figure 5. Side wall venting.
Figure 6. Side wall venting.
9 IN. MAX.
9
2 FT.MIN.
6 IN. MIN.
AIR INTAKE
(DO NOT BL0CK)
S.
TO DRAIN OR
CONTAINER
OUTSIDE WALL
O
OUTSIDE VENT TERMINATION
ELBOW WITH SCREEN
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
12" MIN
SNOW LINE
(SEE DEFINITION)
S
O
VSPH/NDV BOILER
DRAIN & TRAP
CONDENSATION
BUILT-IN
WITH WATER
FILL TRAP
A
3 IN. DIA.
S.S.FLUE
PIPE (SEE
PAGE 5)
A U
A WALL THIMBLE MUST
BE USED ON COMBUSTIBLE
WALLS. S/F P/N 440695
(ADJUSTABLE 5 IN. TO 8 IN.)
MAY BE USED. ABOVE THIMBLE
MUST BE USED WITH HEAT-FAB
SLIP JOINT CONNECTOR
P
PRESS./TEMP.
GAUGE