4.7.4 Automatic Output Disable During LOSXAXB
The XAXB reference clock provides a critical function for the operation of the DSPLLs. In the event of a failure, the device will assert an
LOSXAXB fault. By default all outputs will be disabled during assertion of the LOSXAXB fault.
Table 4.15. Output Automatic Disable on LOL and LOSXAXB Registers
Register Name
Hex Address
[Bit Filed]
Function
OUT_DIS_MSK_LOL
0x0142[1]
Determines if the outputs are disabled dur-
ing an LOL condition.
0: Disable all outputs on LOL (default)
1: Normal Operation during LOL
OUT_DIS_MSK_LOSXAXB
0x0141[6]
Determines if outputs are disabled during
an LOSXAXB condition.
0: Disable all outputs on LOSXAXB (de-
fault)
1: All outputs remain enabled during LOS-
XAXB