Measuring Humidity 

Ambient humidity :

Measurement unit : % rH (percentage of relative humidity)

Display : resolution to 0.5 % rH

Measuring range : from 2 % rH to 100 % rH

Measuring cycle : one measurement carried out every second

Precision : +/- 3.5 %

Response time: In the event of a sudden change in the humidity or temperature, one should
give the sensor enough time to allow it to adapt to the ambient air.

Please refer also to : Response time in the section "Measuring temperature".

Comments : In general, the following facts must be taken into account when measuring :
1. Ambient humidity depends on the temperature. When moving the instrument from a warm

environment to a cold environment, the values measured will vary ;

2. Humidity is not equally distributed in the atmosphere. Consequently, even though two locat-

ions used for measuring may be close to each other, both results may be quite different ;

3. A person perspiring and/or breathing very near the instrument may impact on

themeasurement.

Dew point :

The dew point is calculated by taking into account the humidity and the
ambient temperature. It gives the temperature at which the water vapour
contained in the air has reached saturation point (forming of cloud, fog, dew,
condensation on objects, etc.)

Example : At an ambient temperature of 23°C and with a humidity of 
39.5 % rH, the dew point is at 12°C 

(see Fig. 2)

Display : Press the temperature button      for about one second, then release
it in order to display the temperature of the dew point.
The dew point in °C or °F is then shown in the lower part of the display, using the symbol    .

Measuring Temperature

Ambient temperature :

Measurement units : In order to choose between units, press the temperature button 
for approximately 4 seconds. The following selection will appear: °C (degrees Celsius) and 
°F (degrees Fahrenheit).

Display : resolution to 0.5°C / 1°F

Measuring range : °C from -20 to 80    °F from -4 to 176

Measuring cycle : one measurement carried out every second

Fig. 2

Содержание atmos

Страница 1: ...JDC ELECTRONIC USA PO Box 284 Holmen WI 54636 USA 608 498 4021 phone 608 531 2608 fax warranty jdcusa com www jdcusa com Anemometer Thermometer Hygrometer Owner s Instructions ...

Страница 2: ...conds The following selection will appear km h kilometres per hour mph miles per hour knots m s metres per second and fps feet per second Display Resolution to the unit From 100 units upwards the last digit is displayed smaller than the others Please refer to Fig 1 opposite showing the display of a 112 km h wind Measuring range km h from 3 to 255 mph from 2 to 150 knots from 2 to 150 m s from 2 to...

Страница 3: ...different 3 A person perspiring and or breathing very near the instrument may impact on themeasurement Dew point The dew point is calculated by taking into account the humidity and the ambient temperature It gives the temperature at which the water vapour contained in the air has reached saturation point forming of cloud fog dew condensation on objects etc Example At an ambient temperature of 23 C...

Страница 4: ...e basis of ambient temperature and wind speed In the presence of wind it gives an idea of the body heat loss if the ambient temperature is below 37 C and of the body heat gain should the temperature be above 37 C Example together an ambient temperature of 0 C and a 30 km h wind have the same effect on you as a temperature of 13 C See Fig 3 Display Resolution to the unit You can display the windchi...

Страница 5: ...ps and its shaft from being damaged Even though the electronic components are protected in their casing and the polyethylene foam they do no like shocks You will therefore be well advised to protect your instrument from impact as a result of falls or otherwise Conversion Table for the Various Units of Measurement Beaufort knots km h mph m s fps 1 1 3 1 5 1 3 1 2 1 4 2 4 6 6 11 4 7 2 3 5 10 3 7 10 ...

Отзывы: