UK
The power supply allows 12Vdc units to be powered by the mains. It can supply the rated continuous
current over long periods of time and the peak current over a short period. The power supply features:
-
thermal protection
-
short-circuit protection
Safety Recommendations:
-
Check the housing and the connection lead for damages
-
For indoor use only
-
Do not use the unit in humid rooms
-
Do not let liquids penetrate the ventilation holes
-
Do not connect devices that need higher current outputs than those specified for the unit
-
Do not place the unit in warm locations (max. 30°C)
-
Do not obstruct the ventilation holes or heat sink. Leave enough space around the unit to ensure
sufficient ventilation
-
The heat sink becomes very hot during use. Do not touch it while in use !
-
Unplug the unit from the mains prior to replacing the fuse.
Operation:
-
Connect the unit to be powered to the red and black terminal
red
+
black
-
-
The unit to be powered must not draw more current that the maximum continuous current output
of the power supply in order to prevent overload.
-
Do not operate the unit at full load for longer periods of time
-
Plug the power supply into a wall outlet.
-
Switch the unit on via the power switch. The power LED will light.
Protection:
If one of the built-in protection circuits is activated, proceed as follows:
-
Switch the power supply off
-
Let the power supply cool down if it is hot
-
Before you switch the power supply on again, check if the connected unit does not draw too much
current or is faulty.
-
Check the fuse when the power LED does not light up
Specifications:
All models:
Input voltage 230V / 50 Hz
Output voltage 13,8 Vdc
Model No. Max Current Peak current Weight
650.651
3 Amps
5 Amps
2,5 kg
650.652
5 Amps
7 Amps
2,8 kg
650.654
7 Amps
9 Amps
3,0 kg
650.657
10 Amps
12 Amps
3,5 kg
650.660
15 Amps
17 Amps
4,9 kg
650.663
20 Amps
22 Amps
8,0 kg
650.667
25 Amps
27 Amps
10,0 kg
650.670
40 Amps
42 Amps
18,0 kg
WARNING:
Do not open the case. Risk of electrical shock. Repairs should only be carried out by a
qualified technician.
The Max Current can be supplied continuously for 30 min maximum.