Skytron 4-030-60 Скачать руководство пользователя страница 4

Page 4

This is a high quality OR table accessory that provides the following features and benefits:
                                         

Slides onto the accessory side rail of the surgical table

• 

Facilitates access to the operative site

• 

Permits abduction/adduction of either leg

• 

Permits adjustment of lithotomy position

• 

Adjustable length

• 

Compatible with SKYTRON Table Models: 3500 Series, 3600B, 6002 Series and 6700 Series. This 

• 

accessory has been proven to perform safely with these SKYTRON table models. The safety, com-
patibility and ease of use can only be guaranteed with these models. Use with other tables is not 
recommended.

In order to properly utilize and fully appreciate the SKYTRON Split Leg Section be sure to follow these 
instructions carefully. Initial use should not begin until after the users have been instructed by the manu-
facturers representative. Familiarize yourself with the product illustration prior to proceeding.

As with any unfamiliar patient positioning device, you should always practice its use on a nurse, physician 
or other appropriate volunteer prior to using it clinically.

RAIL LOCK KNOB

ACCESSORY LOCK

HANDLE

LITHOTOMY

LOCK KNOB

SAFETY INFORMATION

WARNING

To prevent failure of the Split Leg do not 
exceed 400 lb. patient weight limit.

WARNING

Do not use Split Leg in reverse Trendelen-
burg position without additional patient 
restraint such as thigh straps.

CAUTION

Split  Leg  Section  should  be  attached 
by at least two trained operators, one to 
support the patient and one to position 
the Split Leg Section.

CAUTION

If it is necessary to reposition the Split 
Leg Section, one operator should always 
support the patient's leg until the Split 
Leg  Section  is  securely  locked  in  the 
new position.

Содержание 4-030-60

Страница 1: ...OWNERS MANUAL UNIVERSAL SPLIT LEG SECTION P N 4 030 60 ACCESSORY FOR 3600B TABLES and the 3500 6002 6700 SERIES TABLES TEC D 0035 REV0 11 09...

Страница 2: ...Page 2 13 4 4 9 4 4 30 36 5 13 4 9 5 24 5 21 GENERAL DIMENSIONS AND SPECIFICATIONS Complete Accessory Weight 31 6 lbs...

Страница 3: ...e joints of the top section should always be considered BE SURETHATTHE ARMS HANDS AND FINGERS OF THE PATIENT AND THOSE OF THE OPERATING ROOM PER SONNEL ARE CLEAR OF ALL MOVING PARTS BEFORE MOVING THE...

Страница 4: ...not begin until after the users have been instructed by the manu facturers representative Familiarize yourself with the product illustration prior to proceeding As with any unfamiliar patient positio...

Страница 5: ...eclampmaybebroken when the table is articulated 4 Whentheproductisinposition tightentheRail Lock Knob securely by turning clockwise to secure Split Leg Section onto surgical table side rail 5 Ensure t...

Страница 6: ...Lithotomy Lock Knob NOTE To obtain maximum service life from this clamp always completely unlock the Rotation Knob by turning it at least two full turns prior to adjusting the angle of inclination RE...

Страница 7: ...e cleaning product s directions and follow the instructions on the label Use caution in areas where fluid migration may occur Handles Side rail clamps 4 Wipe device with a clean dry cloth 5 Make certa...

Страница 8: ...5085 Corporate Exchange Blvd S E Grand Rapids MI 49512 1 616 656 2900 FAX 1 616 656 2906...