Skytech TM-R-2A Скачать руководство пользователя страница 4

Skytech: TM-R-2A

REV. 10-12-18 Page 4

NOTE:

  The remote receiver will only respond to the transmitter when the 3-position slide button on the remote receiver is 

in the REMOTE position.  If the system does not respond to the battery transmitter on initial use, see LEARNING 
TRANSMITTER TO RECEIVER, and recheck battery positions in the remote receiver. 

 

HEARTH MOUNT

        

  

The remote receiver can be placed on the fireplace hearth or 

under the fireplace, behind the control access panel.  Position 

receiver where the ambient temperature inside the case does 

not exceed 130°F.  

NOTE

: Black Slide Button is used for Hearth 

Mount applications.

WIRING INSTRUCTIONS

A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by 

this remote should install the remote-control system.  Incorrect wiring connections WILL cause damage to the gas valve or 

electronic module operating the gas appliance and may also damage the remote receiver.  

WIRING MILLIVOLT VALVES

The remote receiver is connected to the millivolt valve using the TH (thermostat) terminals on the terminal block on the 
millivolt gas valve.  Connect 18 gauge solid or stranded wires from the remote receiver to the gas valve.

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

REMOTE

RECEIVER

Operation of the remote receiver is similar to that of a 

thermostat in that both turn the gas valve ON and OFF based 

on input signals.  A thermostat’s input signals are different 

temperatures. The remote receiver’s input signals come from 

the transmitter.

Connect one of the two wires leading from the receiver to the 

TH terminal and the other to the TH/TP terminal on the millivolt 

gas valve it does not matter which wires go to which terminal.  

The remote control receiver can be connected, in series 

between a 24VAC transformer and the TR terminal on 

the ELECTRONIC MODULE.  Connect the hot wire from 

the 24VAC transformer to either of the wire on the 

remote receiver.  Connect another wire (included) 

between the other receiver wire terminal and the TH 

(thermostat) terminal on the ELECTRONIC MODULE.

ELECTRONIC MODULE

TR

TH

REMOTE

RECEIVER

neutral wire

24VAC

hot wire

120VAC

110/24VAC

Transformer

WIRING ELECTRONIC SPARK IGNITIONS

Отзывы: