Skytech Fire Pits

REV. 11-15-12  Page 5

WARNING: 

Proper clearances from combustible, construction and materials must be maintained from all sides, top and 

bottom of this appliance.  This appliance should never be placed on any combustible surface.  This appliance should 

never be placed under any combustibles closer then 96-inches. This appliance should never be placed closer than 
36-inches from any side to any combustible construction or materials (See fig. 2, pg. 4).

PREPARING A NON-COMBUSTIBLE STRUCTURE

The Fire Pit is to be installed on a flat, stable surface, away from any combustible materials. Install Fire Pit on any level, 

outdoor non-combustible surface. 

NOTE

: Do not place fire pit directly on grass, dirt, or rocks this may prevent proper 

ventilation (Fig. 1, pg. 3).  

HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY

NOTE:

  We recommend using 3/4” black iron pipe however please refer to the NFPA54 (National Fuel Gas Code) for 

proper pipe sizing when exceeding 20-feet in length for fire pits rated above 100,000 Btu’s.

1. Turn 

OFF

 gas supply system. 

NOTE

: All gas connections (except for brass to brass) require the following. Clean pipe 

threads using either a wire brush or steel wool. Apply Teflon tape or pipe sealant to the steel fittings before making any 

connection. 

BE CAREFUL!

 Ensure all gas connections are snug, but not over tighten!

2. Extend the gas supply system using minimum of ¾” black iron pipe or an approved flexible gas line from existing house 

supply.  This can be accomplished by teeing off or tapping into a convenient gas line connection. Install necessary pipe 

for the distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a 

foundation or house wall, make sure to re-seal the area around the pipe with weather sealant.

3. From manual valve, extend gas pipe to the Fire Pit location. 

NOTE:

 If pipe is to be placed in an underground trench, 

check with local codes for required depth and materials needed. 

4. Install a ¾” female x ½” male flared brass fitting to the end of the ¾” black iron pipe.  Be sure to clean the pipe threads 

and use Teflon tape or pipe sealant.  

5. Connect the ½” female flared flex connector from the Fire Pit to the ½” male flared brass fitting secured to the black iron 

pipe. 

Note

: Flare to flare connections do not require Teflon tape or pipe sealant.

IMPORTANT

Installation of Natural or LP gas should be done by a qualified installer, service agency or gas supplier.

The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any   

pressure testing of the system at test pressure testing of the system at test pressures in excess of ½ psig (3.5kPa).

This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any 

pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa)

NOTE: 

LP conversion kits are available in the Replacement Parts 

section of this manual.  When converting a Fire Pit ensure you 

follow the instructions supplied with the 
conversion kit

.

VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE

Fire pits are subjected to many outdoor elements such as 

rain, snow, wind, heat or cold.    

A minimum of 18 square 

inches of cross ventilation (2 sides) is required to keep the 

components in good working order. 

 Use figure 3 as guide 

to assist to incorporate proper ventilation.  

NOTE

: Ventilation is 

not required at the bottom and may also be incorporated in the 

upper portion of an enclosure.

Fire Pit 

Enclousure

2”x3” 

Fire Pit

Examples of Cross Ventilation

3 - 2”x3” Slots Per Side or

2-  1” x 9” Slots Per Side

Cross Flow  Ventilation 

(Min. 18 Sq. In. Per Side)

Figure 3. Cross Ventilation Example

HIGH ELEVATION INSTALLATION

This appliance is listed for elevations from 0-4500 feet in 

Canada and the U.S.  If elevation exceeds 4500 feet it may be 

necessary to decrease the input rating by changing the exist-

ing burner orifice to a smaller size.  Input should be reduced 

4% for each 1000 feet beyond the 4500 feet above sea level. 

Check with your local gas utility for assistance in determining 

the proper orifice in your location.  In some cases the heating 

value may already be reduced and downsizing the orifice may 

not be necessary.

Содержание SSB10

Страница 1: ...STALLATION PRECAUTION This fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Match Light Description Piezo Spark Ignition SSBPR19 19 Rd Pan Spoke Burner SSBPR19PSI SSBPR25 25 Rd pan Spoke Burner SSBPR25PSI SSBPS20 20x20 Sq pan Spoke Burner SSBPS20PSI SSBPS26 26x26 Sq pan Spoke Burner SSBPS26PSI Burners Only SSB10 ...

Страница 2: ...6673589 958 6 9 95 8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2...

Страница 3: ...hes 3 23 cm for each pound of propane LP contained in the tank see example below Every opening must have minmum dimensions to allow entrance of a 1 2 3 2 mm diameter rod Ventilation openings in side walls must not connunicate directly with other enclosures of the fire pit The cyclinder valve must be easily accessible by hand Connections should be easy to leak test inside the enclosure A door on th...

Страница 4: ...6 Installing Key Valve Piezo Ignitor 6 Typical Installation Drawings 7 Installing Battery in Piezo Ignitor 8 Ignitor Alignment 8 Installation of Lava Rock Media 8 Operation 9 Lighting Instructions 9 Air Shutter Adjustment 9 Replacement Parts 10 Replacement Parts List 11 Fire Pit Maintenance Trouble Shooting 12 Optional Accessories Conversion Kits 12 13 Warranty 14 TABLE OF CONTENTS NOTE This insta...

Страница 5: ...5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level SSBPR19 Rd 2 625 19 25 21 5 19 8 SSBPR25 Rd 2 625 25 25 27 5 25 8 SSBPRS20 Sq 2 625 20 25 21 75 20 8 SSBPRS26 Sq 2 625 26 25 27 75 26 8 Note Fire pits are rated at maximum Btu s which is dependent upon proper gas pipe sizing Flex line size also affects Btu s As a r...

Страница 6: ...ting to the end of the black iron pipe Be sure to clean the pipe threads and use Teflon tape or pipe sealant 5 Connect the female flared flex connector from the Fire Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service...

Страница 7: ...d or non combustible logs may be added for a campfire look If logs are chosen do not place on decorative glass base use only Lava Rock as the base NOTE If using all glass media glass must be a minimum of 1 4 inch diameter or larger 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections must be leak tested before installation of the fire pit Soapy water ...

Страница 8: ...terial Non Combustible Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Non Combustible Wall Material Non Combustible Wall Material Securing Tab Securing Tab Self Securing Junction Box Piezo Ignitor Mounting Plate Piezo Wires P i ezo Ignitor Side View Det a i l Fig 5 Typical installation NOTE Gas supply shut off and flex line to the key valve are not supplied ...

Страница 9: ...ry in order to spark operate Unscrew counter clockwise the piezo ignitor cap See fig 6 and insert the positive end of the battery into the ignitor body Screw the cap clockwise until snug See fig 7 Careful not to overtighten the cap Test the ignitor by pushing and holding the red button to ensure the ignitor probes inside the fire pit are sparking The spark should be located directly overtop of the...

Страница 10: ...NG TO LIGHT FIRE PIT CAUTION Ensure you have leak tested the fire pit before operating 1 Insert key into gas valve 2 Push and hold the red button on the manual Piezo ignitor and ensure sparking is occurring at the probes inside the fire pit 3 Rotate the key counter clockwise in gas valve to allow gas to flow 4 Gas should ignite within 10 seconds or less If fire pit does not light within 10 seconds...

Страница 11: ...REV 11 15 12 Page 11 REPLACEMENT PARTS 1 2 4 7 5 6 O N O F F Side View 8 9 10 11 12 15 3 Skytech Matchlight Fire Pits ...

Страница 12: ...on 10 Fire Pits 1 O AS 42 7 Orifice Air Shutter LP Used on 10 Fire Pits 1 O AS 51 7 Orifice Air Shutter NG Used on 19 20 Fire Pits 1 O AS 28 7 Orifice Air Shutter LP Used on 19 20 Fire Pits 1 O AS 39 7 Orifice Air Shutter NG Used on 25 26 Fire Pits 1 O AS 19 7 Orifice Air Shutter LP Used on 25 26 Fire Pits 1 O AS 32 8 Manual Spark Ignitor Module 3042 RB 1 ST3 040 1020 9 Manual Spark Ignitor Module...

Страница 13: ...nce REV 11 15 12 Page 13 OPTIONAL ACCESSORIES The following accessories are available from your local firegear dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing TROUBLE SHOOTING Sympton Remedy Piezo won t spark 1 Be sure battery is installed properly 2 Check battery voltage Min 1 2 VDC needed 3 Check ignitor gap at probes...

Страница 14: ... Company or owner is not covered by this warranty Modification of the Skytech product will void this warranty IN NO EVENT SHALL SKYTECH BY LIABLE FOR INCIDENTAL AND CONSEQUENTIAL INCLUD ING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY THIS WARRANTY SUPERSEDES ALL OTHER ORAL OR WRITTEN WARRANTIES Some states do not allow the exclusion or...

Отзывы: