background image

REV. 3-26-19 Page 3

Skytech: Smart Stat-IV

WARNING

This remote control system must be installed exactly as outlined in these instructions.  Read all instructions completely before 

attempting installation.  Follow instructions carefully during installation.  Any modifications of this remote control or any of its 

components will void the warranty and may pose a fire hazard.

Consult gas appliance manufacturer’s instructions and wiring schematics for proper placement of all wires.  All electronic modules 

are to be wired to manufacturer’s specifications.

The following wiring diagrams are for illustration purpose only.  Follow instructions from manufacturer of gas valve and/or electronic 

module for correct wiring procedures.  Improper installation of electric components can cause damage to electronic module, gas 

valve and remote receiver.  

WIRING INSTRUCTIONS

A qualified electrician should install the remote control system.

MILLIVOLT VALVES

MILLIVOLT SYSTEM CHECK

• 

Ensure that the pilot flame is lit.

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The 

main gas flame (i.e., the fire) should ignite. 

• 

Slide the button to 

OFF

.  The main flame should extinguish (the pilot flame 

will remain on).

• 

Slide the button to 

REMOTE

, then press the 

ON

 button on the transmitter to 

change the system to on. The main gas flame should ignite.

• 

Connect one wire from the remote receiver to the TH terminal on the gas 

valve.

• 

Connect the other wire from the remote receiver to the TH/TP terminal on 

the gas valve.

The remote control receiver can be connected, in series, to a 24VAC transformer to 

the TR (transformer) terminal on the ELECTRONIC MODULE.  Connect the hot wire 

from the 24VAC transformer to either of the wires on the remote receiver. Connect 

the other wire from the receiver to the TH (thermostat) terminal on the ELECTRONIC 

MODULE.

ELECTRONIC SPARK IGNITION 24 VAC INPUT

• 

Before installation, make sure you turn the slide switch to 

OFF

. After installation, make sure you turn the slide switch to 

REMOTE

.

• 

The remote receiver can be placed on the fireplace hearth or under the fireplace behind the control access panel. 

• 

Use the wires attached to the remote receiver to connect to the gas valve or the electric module (piggyback connectors have both 

male & female terminals for flexibility).

• 

Be sure that the connectors do not touch each other or other bare metal surfaces; this will cause the appliance to turn on. The   

connectors may be wrapped with electrical tape to prevent this.

INSTALLATION

Protection from extreme heat is very important. The remote receiver should be kept away from temperatures exceeding 170ºF. Extreme 

heat can cause damage, which is not covered under warranty.

REMOTE RECEIVER

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

ELECTRONIC MODULE

TR

TH

neutral wire

24VAC

hot wire

110/24VAC

Transformer

REMOTE RECEIVER

To 110 Power

To 110 Power

Содержание Smart Stat-IV

Страница 1: ...1 Low Battery Indicator Battery power is low replace batteries within two weeks 2 Timer Time remaining before the system shuts off 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Se...

Страница 2: ...be away from your home for an extended period of time The remote receiver is manufactured with a dry contact relay in its circuitry that operates like an on off switch However no power or current pass...

Страница 3: ...ect one wire from the remote receiver to the TH terminal on the gas valve Connect the other wire from the remote receiver to the TH TP terminal on the gas valve The remote control receiver can be conn...

Страница 4: ...ed When this mode is engaged all auto settings go on without interruption like thermostat Only manual functions are prevented BATTERY LIFE Life expectancy of the alkaline batteries in the transmitter...

Страница 5: ...SIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODI FICATIONS TO THE EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT For Technical Service call U S...

Страница 6: ...tomer s compliance with all terms and conditions contained herein governing service and claims under the Warranty Skytech shall provide replacement parts at no charge for the first 5 five years of thi...

Страница 7: ...above limitation may not apply to you This warranty gives you specific rights and you may have other rights which vary from state province or nation To the extent allowable under any law the liability...

Отзывы: