OPERATION
The speed control will turn ON the fan automatically 7 minutes after the main flame has been turned ON and turn the fan
OFF 12 minutes after the main flame has been turn OFF. There are four speeds, Hi, Medium Hi, Medium Lo, Lo and OFF.
Manually adjust fan speed by pressing the FAN SPEED button on the FK-ESC.
To check the fan for proper wiring press the TEST button. This is a manual override that will operate the fan on HI as long
as the button is depressed. The FK-ESC will remember the last setting used and remain on that setting until changed.
OPTIONAL ACCESSORIES
16 SPT 2 – Optional 16-inch extension cord to plug into junction box for greater mobility of the FK-ESC.
MAINTENANCE
Cleaning on a semi-annual basis is required to keep the warranty in place. Dust or dirt must be removed from the fan
blades, air inlets and blower outlet for the fan kit to maintain the efficiency of the system. Carefully use a vacuum with a
brush to remove any dust. If unable to reach fan with a vacuum remove the fan from the appliance for easier cleaning.
!
!
Recognized component according to UL 1004-1 and UL 1004-3 and CSA C22.2 No. 100-04 and CSA C22.2
No 77-95 R2004
NEUTRAL
HOT
5 4 3 2 1
5 4 3 2 1
FAN
REM/AUX
TRANS
Jumper
Wire
Power Strip
1/4” Female Connectors
!
When plugging in the FK-ESC into a 120VAC power source, some fireplaces use a standard metal junction box and other
fireplaces may use a power strip. If a power strip is used (as shown below in figure 4) and no power is found in the FAN
outlet use the red jumper wire with the 1/4” connectors and attach as shown below. With the jumper installed the FAN
outlet will provide the power necessary to operate the FK165-1 system.
POWER SOURCE INFORMATION
Fig. 4 Power strip jumper connection
Skytech FK-165-ESC
REV 4-10-12 Page 4 of 5
Toll-Free
1-866-667-8454
NorthlineExpress.com
www.NorthlineExpress.com
Toll-Free
1-866-667-8454
NorthlineExpress.com
www.NorthlineExpress.com