REV 12/26/07
Page 2 of 6
LOCATING THE RECEIVER
PROTECTION FROM EXTREME HEAT IS VERY IMPORTANT. Like any piece of electronic equipment, the remote receiver should be
kept away from temperatures exceeding 130
0
F. Exposure to extreme temperatures can damage the electronic components or cause
the plastic case to become deformed and is not covered under warranty.
WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote
should install the remote control system. Incorrect wiring connections
WILL
cause damage to the gas valve or electronic module
operating the gas appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES
The remote receiver is to be connected to the millivolt valve.
Connect one of the (2) 18 gauge wires from the 1410-A receiver to the TH terminal and
the other to the THTP terminal on the terminal block on the millivolt gas valve.
Operation of the remote receiver is similar to that of a thermostat in that both turn the gas
valve on and off based on input signals. A thermostat’s input signals are different
temperatures. The remote receiver’s input signals come from the transmitter.
WIRING ELECTRONIC SPARK IGNITIONS
Most electronic systems operate on a 110 VAC/24VAC power transformer used to power
the system electronic ignition module and electronic gas valve, which can be controlled by
the 1410-A remote receiver as, illustrated.
NOTE
: THE 110-120 VAC/ 24VAC, transformer may be purchased from your appliance
dealer, or an electronic parts distributor.
The remote control receiver can be connected, in series, to a 24VAC transformer to the
TR (transformer) terminal on the ELECTRONIC MODULE. Connect the hot wire from the
24VAC transformer to either of the wires on the remote receiver. Connect the other wire
from the receiver to the TH (thermostat) terminal on the ELECTRONIC MODULE.
WARNING
THIS REMOTE CONTROL SYSTEM MUST BE INSTALLED EXACTLY AS OUTLINED IN THESE INSTRUCTIONS. READ ALL
INSTRUCTIONS COMMPLETELY BEFORE ATTEMPTING INSTALLATION. FOLLOW INSTRUCTIONS CAREFULLY DURING
INSTALLATION. ANY MODIFICATION OF THIS REMOTE CONTROL OR ANY OF ITS COMPONENTS WILL VOID THE WARRANTY
AND MAY POSE A FIRE HAZARD.
1 2 3 4 5 6
REMOTE RECEIVER
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
THERMOPILE/
PILOT LIGHT
110/120VAC
input
1 2 3 4 5 6
110/120VAC
input
REMOTE RECEIVER
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
110/24VAC
Transformer