Skytech 1001BE
Operation of the remote receiver is similar to that of a thermostat in that both turn
the gas valve on and off based on input signals. A thermostat’s input signals are
different temperatures. The remote receiver’s input signals come from the
transmitter.
Connect each of the three (3) wires leading from the receiver to the TH, TP, and
TH/TP terminals on the millivolt gas. These (3) wires are marked TH, (Black
Wire) TP, (Red Wire) and TH/TP (White Wire)
SYSTEM CHECK
MILLIVOLT VALVES
Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.
Note: Always check for any gas leaks and follow all the instructions from the manufacturer of the appliance on the start up
procedures of the appliance.
1. Allow the thermopile to completely heat up, for at least 5 minutes. (Note: If you have a Ventfree product, you may want to
allow a longer heat up time, up to 10 minutes.
2. Once the thermopile has heated up, turn the main valve knob from the
PILOT
position to the
ON
position.
3. To activate the power going to the remote control receiver from the thermopile you will need to PUSH and HOLD the
System
Energize
button on the receiver for a minimum of 60 seconds before releasing the button. This will start the process of converting
millivolts from the thermopile into DC volts required to operate the receiver. This will continue for as long as the thermopile is in
operation.
4. Use the transmitter of the remote control to activate the main burner of the appliance.
5. Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.
6. Slide the button to OFF. The flame should extinguish (the pilot flame will remain on).
7. Slide the button to REMOTE (the center position)
8. Press the ON button on the transmitter to turn the system to ON. The main gas flame should ignite.
9. Press the OFF button on the transmitter to turn the system to OFF. The flame should extinguish (the pilot flame will remain on).
Note: The 1001 BE system will need to be re-energized if the
remote receiver has been turned to the manual ON or OFF
position. This is done by depressing and holding the
SYSTEM
ENERGIZER BUTTON for minimum of 60 seconds.
Note: The 1001 BE system will need to be re-energized every
time the pilot light is turned to the OFF position or the pilot
light goes out for any reason. This is done by depressing
and holding the SYSTEM ENERGIZER BUTTON for
minimum of 60 seconds.
Note: The Energizer Button must be held in for minimum of
60 seconds
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
THERMOPILE/
PILOT LIGHT
REMOTE
RECEIVER
REMOTE
ON
OFF
LEARN
ENERGIZE
^
ADJ.
White Wire TH/TP
Red Wire TP
Black Wire TH
Energize Button