AIR PRESSURE HISTORY BAR CHART
1.
The bar chart indicates the air pressure history trend over the last 12 hours in 6 steps: 0h, -1h, -2h,
-3h, -6h and -12h.
2.
The “0h” represents the current full hour air pressure recording.
3.
The columns represe
nt the “inHg” at specific time.
4.
If the bars are rising it means that the weather is getting better due to the increase of air pressure.
5.
If the bars go down, it means the air pressure has dropped and the weather is expected to get
worse
from the present time “0h”.
Remarks: Moving your weather from one floor of a building to another floor will affect the accuracy of
your weather station, which should operate at the same altitude all the time. If you move it to a new
location, it will take 12-24 hours to get stable and accurate again.
Our weather station provides next 12-24 hours weather forecast. It may not match with the current
weather condition outside.
TO READ MAXIMUM-MINIMUM INDOOR-OUTDOOR TEMPERATURES AND HUMIDITIES
Simply press the
MAX-MIN
button to view the maximum indoor and outdoor temperatures and
humidities with “
MAX
” icons appearing on the display. Press again to view the minimum indoor and
outdoor temperatures and humidities with “
MIN
” icons appearing on the display.
When the maximums or minimums are displayed, press and hold the
MAX-MIN
button to reset both
records and it will start to record the maximums and minimums again.
IF YOU LOSE THE OUTDOOR TEMPERATURE AND HUMIDITY
When the outdoor temperature and humidity digits show '---", the wireless transmission is either
interrupted or lost. Press and hold the
MAX-MIN /
OUT TEMP
button on the clock once. If you continue
to lose the outdoor temperature display, try placing the transmitter in a different location until you have
smooth transmission of temperature data.
TROUBLESHOOTING
In case your weather station clock shows irrelevant information or digits, it maybe affected by
electrostatic discharge or interferences from other devices. Press the
RESET
button on the top right of
your unit. Your unit will be reset to default settings and it will start to receive outdoor temperature and
humidity and then WWVB signal again.
Problem
Solution
LCD is blank
1.
Press RESET on the main unit.
2.
Check if AC/DC adaptor or DC jack is loose or unplugged.
No Outdoor Temperature and
Humidity is displayed
1.
Press and hold MAX-MIN / OUT TEMP on the weather
station.
2.
Press and hold MAX-MIN / OUT TEMP, then press RESET on
the outdoor sensor.
3.
Observe if the Low Battery icon appears on the left of the
outdoor temperature. If yes, replace batteries in outdoor
sensor with fresh alkaline batteries.
4.
No other interfering sources are being used (such as
computer monitors, TV sets, headphones, or speakers) in the
path of signal from the outdoor sensor. The signal travels in a
straight line, an electrical source near that “line” may cause
interference.
Temperature, humidity, or air
pressure is incorrect
1.
Press RESET on the main unit.
2.
Make sure your main unit and the outdoor sensor is away
from sources of heat / cold / direct sunshine.