background image

 

 
 
1. 

ALARM ON:

  

 

Press it to turn the alarm and snooze on or off.  

 

In normal time mode, press and hold it for 2 seconds to enter the alarm and pre-alarm 
setting mode.  

 

2. 

TIME:

  

 

Press it once to view the Dew Point.  

 

Press and hold it for 2 seconds to enter the time setting mode.  

 

 
 
3. 

UP:

  

 

In normal time mode, press it to choose between channel (1),(2) and (3).  

 

In setting mode, press it to increase the setting value.  

 
4. 

SNOOZE:

  

 

Press it to stop alarm when it is sounding.  

 

Press and hold it for up 8 seconds to stop current RC reception.  

Содержание 81690

Страница 1: ...ity measured and transmitted by the sensor It is able to receive and display readings from up to 3 remote sensors The receiver unit retains the minimum and maximum temperatures and relative humidity r...

Страница 2: ...mode 2 TIME Press it once to view the Dew Point Press and hold it for 2 seconds to enter the time setting mode 3 UP In normal time mode press it to choose between channel 1 2 and 3 In setting mode pre...

Страница 3: ...etween C F 11 RESET Press it to set all values to factory value In case of mal function the unit may be required to reset 12 TABLE STAND Use to stand on desktop 13 WEATHER FORECAST WINDOW Displays the...

Страница 4: ...week 20 CLOCK WINDOW Displays the time and radio controlled signal TRANSMITTER 1 LED indicator Flashes when the remote unit transmits a reading 2 LCD Displays the current temperature and humidity moni...

Страница 5: ...o each transmitter Channel 1 2 or 3 respectively by sliding the switch inside the battery compartment 4 Press the reset key of the transmitter individually by a pin to confirm the channel setting 5 Sl...

Страница 6: ...nd date are automatically synchronized with the time signal transmitted from Ft Collins Colorado provided the device is within about 2 000 miles of the transmitter When used for the first time after i...

Страница 7: ...he clock will automatically synchronize with the exact time 1 In normal time mode press and hold TIME key for 2 seconds hour flashing press UP or DOWN key to change its value 2 Press TIME key again mi...

Страница 8: ...omatically turn on when setting the alarm time 2 Once the snooze is turn on the 4 step crescendo alarm will sound 4 times in 5 minute interval The alarm duration is 120 seconds Alarm OFF Alarm ON Alar...

Страница 9: ...eceived or the transmission is interfered with appears in the display 2 Relocate the clock or the transmitter to another position and make sure the transmission is within the effective range of 100 fe...

Страница 10: ...tice atmospheric pressure changes Based on the data collected it can predict the weather condition in the forthcoming 12 24 hours The effective cover area ranges from 15 to 30 miles NOTE 1 The accurac...

Страница 11: ...he HISTORY button Each press on the button will go back by an hour The recorded atmospheric changes for the past 24 hours are displayed in a bar chart above the atmospheric pressure window ABOUT THE M...

Страница 12: ...n ecologically safe manner USING THE TABLE STAND OR WALL MOUNTING The receiver has both the desk top and wall mounting structure For the receiver place the screw provided on the desired wall and hang...

Страница 13: ...Resolution 1 RH REMOTE SENSOR Temperature measuring range 20 C to 60 C Recommended operating range 20 C to 55 C Temperature resolution 0 1 C 1 F above0 C 1 C F below 0 C RF transmission frequency 433...

Страница 14: ...n material and workmanship During this period such defects will be repaired or the product will be replaced at Equity s option without charge This model is discontinued and is not eligible for the man...