SPECIFICATIONS

Specifications  are  typical;  individual  units  might  vary.  Specifications  are  subject  to  change  and 
improvement without notice.

    2020 SkyRC Technology Co., Ltd. All Rights Reserved. No part of these manual may be 
reproduced without the written permission of SkyRC Technology Co., Ltd.

 

Printed in China. 

Manufactured by

SKYRC

TECHNOLOGY

CO

.,

LTD

.

www.skyrc.com

7504-1444-01

3

4

WARRANTY AND SERVICE

We guarantee this product free of manufacturing and assembly defects for one year from the time of 
purchase. The warranty only applies to material or operational defects, which are present at the time of 
purchase.  We  will  repair  or  replace  free  of  service  charge  for  products  deemed  defective  during  that 
period due to those causes.

This warranty is not valid for any damage or subsequent damage arising from misuse, modification 
or failure to observe the procedures outlined in this manual. The warranty service is valid in China 
only.

If  you  seek  warranty  service  overseas,  please,  in  the  first  instance,  contact  your  dealer,  who  is 
responsible  for  processing  guarantee  claims.  Due  to  high  shipping  cost,  complicated  custom 
clearance  procedures  to  ship  back  to  China,  please  understand  SkyRC  can't  provide  warranty 
service to the overseas end user directly.

If you have any questions which are not mentioned in the manual, please feel free to send an email 
to [email protected]

Note:

1.

2.

3.

Unplug the Power Supply from the AC outlet to protect it during lightning or when it is left unattended 
and unused for a long period. This will prevent damage to the power supply from lightning and power 
surges.

Unplug the power supply from the outlet before attempting any maintenance or cleaning. Do not use 
liquid or aerosol cleaners. Use a damp cloth for cleaning and then wipe it dry immediately.

If your power supply does not operate normally, in particular, if any unusual sounds or smells coming 
from it, unplug it immediately and contact a qualified service technician for repair.

Input  Voltage……………………………………………………………………………………………100-240V  AC
Input  Frequency………………………………………………………………………………………………50-60Hz
Output Voltage………………………………………………………………………………………12-18V DC±0.5V
Output Current…………………………………………………………………………………………………30A±1A
Current Overload Protection……………………………………………………………………………≤31A 500MS
Input Fuse…………………………………………………………………………………………………… 10A Fuse
LCD Display…………………………………………………………………………………Voltage Precision ±0.3V
                                                                                                                                    Current Precision±0.3A
Output  Voltage  Ripple………………………………………………………………………………………<  900mV
Power  Efficiency…………………………………………………………………………………………………  89%
Power  Factor……………………………………………………………………………………………………>  0.98

o

Over  Temperature  Protection…………………………………………………………………………………<65 C
Cooling  Method…………………………………………………………………………………………Cooling  Fan

o

Operating  Temperature………………………………………………………………………………………0-40 C
Operating  Humidity……………………………………………………………………………………………0-90%
Dimensions  (L*W*H)………………………………………………………………………………218x139x59.5mm
Net weight………………………………………………………………………………………………………1.62kg

Warning

:

This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities or lack of experience and knowledge unless they have been given supervision 
or instruction concerning the appliance's usage by a person responsible for their safety.

This unit is for indoor use only.

Children  must  be  supervised  to  ensure  that  they  do  not  play  with  the  appliance.  WARNING:  If  the 
surface is cracked, switch it off to avoid the possibility of electric shock.

REGULATORY INFORMATION

eFUEL 30A Switching DC Power Supply satisfies all relevant and mandatory CE directives and FCC Part 15 Subpart B: 
2011. The product has been tested to meet the following technical standards:

This symbol means that you must dispose of electrical from the General household waste when it reaches 
the  end  of  its  useful  life.  Take  your  charger  to  your  local  waste  collection  point  or  recycling  center.  This 
applies  to  all  European  Union  countries  and  other  European  countries  with  a  separate  waste  collection 
system.

Test Standards

Title

Result

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Conform

Power Line Conducted Emission Test (150KHz To 30MHz)

Radiated Emission Test(30MHz To 1000MHz)

Power Line Conducted Emission Test (150KHz To 30MHz)

Audio/Video, Information and communication technology

equipment part 1: Safety requirement

Voltage Fluctuations and Flicker Test

Harmonic Current Test

Electrostatic Discharge immunity Test

RF Field Strength susceptibility Test

Electrical Fast Transient/BurstImmunity Test

Surge Immunity Test

Injected Currents Susceptibility Test

Voltage Dips and Interruptions Test

Radiated Emission Test(30MHz To 1000MHz)

FCC Part 15 Subpart B

FCC Part 15 Subpart B

EN-55032-2012

EN 62368-1:2014+A11:2017

EN 61000-3-3: 2013

EN 61000-3-2: 2006+

A1:2009+A2:2009

EN 55024:2010

EN 55024:2010

EN 55024:2010

EN 55024:2010

EN 55024:2010

EN 55024:2010

EN55032:2012