INITIAL PARAMETER SETUP (USERS SET UP)
NIMH Sensitivity
D.Peak Default
NICD Sensitivity
D.Peak Default
Temp. Cut-off
ON 80C
INC
DEC
INC
DEC
- +
INC
DEC
- +
INC
DEC
INC
DEC
- +
INC
DEC
INC
DEC
- +
INC
DEC
INC
DEC
INC
DEC
- +
INC
DEC
- +
recognizes the cell count incorrectly at the
beginning of charge or discharge process, you
may extend the time. Otherwise, you had better
use with the default value.
This shows the trigger voltage for automatic
charge termination of NiMH and NiCd battery.
The effective value ranges from 5 to 20mV per
cell. If the trigger voltage is set higher, there is
a danger of overcharging the battery; if it is set
lower, there is a possibility of premature
termination. Please refer the technical
specification of the battery. (NiCd default: 12mV,
NiMH default: 7mV)
An optional feature using temperature probe
contacting the surface of battery, the temperature
cut-off can be on or off. If it is on, set the
maximum temperature at which the charger
should allow battery to reach during charge.
Once a battery reaches this temperature during
charge, the process will be terminated to protect
the battery.
Waste time
CHG/DCHG 5min
The battery becomes warm after cycles of
charge/discharge process. The program will
insert a time delay after each charge/discharge
process to allow the battery enough time to cool
down before beginning next cycle of charge/
discharge process. The valid value ranges from
0 to 60 minutes.