Skypatrol SP2600 Скачать руководство пользователя страница 26

27

SP2602

 User Manual

Set Report Interval Mode Switching Condition

Command:

DNU command is to set conditions to switch between mode0(dynamic mode) and 
mode1(static mode). Set DNU command will affect the GPRS, SMS administrator, user 
report interval.

Command format:
< User Password>,DNU;<Parameter>

Parameter description:
<Parameter>:HEX, Range is “0 to FF”
Bit7-Bit0 function definition as follow:
Bit0:Parking
Bit1:Domestic roaming
Bit2:International roaming
Bit3:Using backup battery
Bit4:ACC OFF
Bit5 - Bit7:Undefiniton 
Bit states definition:
”0”: Disable 
“1”:Enable

Example:

Device always stick to mode0 interval only.
1234,DNU;0 
Enable Parking condition
1234,DNU;1
Enable Parking and ACC OFF conditions
1234,DNU;11

Содержание SP2600

Страница 1: ...SP2600...

Страница 2: ...not be reproduced for any purpose whatsoever or transmitted in any form either electronically or mechanically including photocopying and recording Skypatrol Company Ltd shall not be liable for direct...

Страница 3: ...ime storage need regular charged to avoid over discharge and need store in the dry and cool place if the storage time is longer than three months The device uses a 8V 32V DC power supply The nominal v...

Страница 4: ...ting Started 11 The Backup Battery Switch 11 Open The Case 12 Insert SIM Card 13 Lock SIM Card Slot 14 Close The Case 15 Install Direction 16 Installing the External GPS Antenna Optional 17 Interface...

Страница 5: ...Interface 32 1 Wire Bus 33 User Combine Command 34 SMS Report Explanation 35 Common commands 38 Set User Phone Number 38 Set User Password 39 Set Report Interval Mode Switching Condition 40 Set Positi...

Страница 6: ...vans fixed plant construction equipment in shore boats and truck trailers It can also be used for temporary tracking of vehicles for consignment purposes as well as covert slap and track operations It...

Страница 7: ...al DC 8 to 32V Backup battery Type Rechargeable Li Po 3 7V 750mAh Power consumption 230mA Active Tracking 25mA Power Saving Mode 10mA Deep Sleeping Mode GSM GPRS Model Built In Air Prime HL6528 Quad b...

Страница 8: ...P2602 User Manual Product overview Check Part List Before starting check all the following items have been included with your device If anything is missing please contact your supplier Standard Part L...

Страница 9: ...USB Cable Relay Fastening Tape Fuse 9 SP2602 User Manual Optional Part List...

Страница 10: ...10 SP2602 User Manual Getting Started Open The Case Forced open up via the gap...

Страница 11: ...11 SP2602 User Manual Open The Sim Card Cover Disconnect the battery and device first and then open the cover...

Страница 12: ...12 SP2602 User Manual Insert SIM Card Insert the SIM card into the holder and please notice the cut mark position Device use 1 8V or 3 3V Micro SIM card SIM card size 12 15mm...

Страница 13: ...13 SP2602 User Manual Lock SIM Card Slot Close the SIM card slot and lock it Connect the battery connection...

Страница 14: ...14 SP2602 User Manual Close The Case Place the cover on the bottom in the position as shown in the photo and close until it snapped...

Страница 15: ...r Manual Installation Direction Device have built in GSM and GPS antenna the signal of GSM and GPS will be affected by installation direction of device The recommended installation direction is as fol...

Страница 16: ...stomized by the customer the following is the definition of the 4 I O connectors device Colour Name Definition Remark Default Black GND Negative Red VCC Positive 8V 32V DC White ACC ACC Ignition signa...

Страница 17: ...nd GND are the power input pins The input voltage range for this device is from 8V to 32V The device is designed to be installed in vehicles that operate on 12V or 24V systems without the need for ext...

Страница 18: ...200 mA Each output has the built in over current and recovery PTC fuse Logical State Electrical Characteristics Enable 1 5 20V Ids 200mA Disable Open drain Device can be configured as digital output...

Страница 19: ...20 SP2602 User Manual Out1 connect to relay 50 CM 85 87 30 87a 86...

Страница 20: ...NO 139 12345678 UPW 4567 USP0 1 24 H 0 W Command Reply Explanation After device received the user s command will immediately to process and use SMS reply to the user reply SMS has two kinds command er...

Страница 21: ...of positioning data W Mode Report Content of message Explanation G3C V1 00 LTM 2013 06 06 14 17 12 http maps google com maps q ETD 28 ACC ON GSM 52dBm EXT_PWR 12 08V BAT 3 86V 301 Device name Firmware...

Страница 22: ...ETD 28 ACC ON GSM 52dBm EXT_PWR 12 13V BAT 3 96V 28 Device name Firmware version Date Time HDOP ALTITUDE in meter Fixed satellite number Time of first fixed N means north S means south E means east W...

Страница 23: ...Time Base station information type Main station MCC MNC Local area code Station ID Signal strength Neighbor station 1 Neighbor station 2 Event ID User defined event name Data GSM network signal streng...

Страница 24: ...default password is 1234 User1 s factory default password is 1234 Command format 1 Set user0 phone number User0 Password UNO0 New phone number 2 Set user1 phone number User1 Password UNO1 New phone n...

Страница 25: ...factory default password is 1234 Changing the factory password at the first usage is highly suggested Command format 1 Set user0 password User0 Password UPW0 New Password 2 Set user1 password User1 P...

Страница 26: ...mmand format User Password DNU Parameter Parameter description Parameter HEX Range is 0 to FF Bit7 Bit0 function definition as follow Bit0 Parking Bit1 Domestic roaming Bit2 International roaming Bit3...

Страница 27: ...rval Report mode Data format Parameter description Mode 0 Report mode0 It s called dynamic mode 1 Report mode1 It s called static mode Valid only when command DNU is enabled Interval Report interval r...

Страница 28: ...29 SP2602 User Manual Example Set User0 dynamic report interval 1234 USP0 0 1H G W Disable User0 static report interval 1234 USP0 1 24H O W...

Страница 29: ...description APN 1 to 64 characters user name 0 to 32 characters password 0 to 32 characters If there is not user name and password for APN command could be APN APN Note Device already save some APN in...

Страница 30: ...maximum TCP Port TCP port UDP Port UDP port Mode 0 TCP mode 1 UDP mode 2 TCP channel for command UDP channel for data report Enable ACK 0 Disable 1 Enabled for UDP this is default setting 2 Enabled f...

Страница 31: ...t as TCP socket 1234 SVR 114 142 154 28 3032 0 0 or 1234 SVR www anytracking net 3032 0 0 Set as UDP socket 1234 SVR 114 142 154 28 3032 1 1 or 1234 SVR www anytracking net 3032 1 1 Delete main server...

Страница 32: ...y Command format User Password BSV IP address TCP Port UDP Port Mode Enable ACK Parameter description IP address IP or domain name 64 characters maximum TCP Port TCP port UDP Port UDP port Mode 0 TCP...

Страница 33: ...t as TCP socket 1234 BSV 114 142 154 28 3032 0 0 or 1234 BSV www anytracking net 3032 0 0 Set as UDP socket 1234 BSV 114 142 154 28 3032 1 1 or 1234 BSV www anytracking net 3032 1 1 Delete main server...

Страница 34: ...e 0 Report mode0 It s called dynamic mode 1 Report mode1 It s static mode Valid only when command DNU is enabled Interval Report interval range is 5 to 900 seconds 15 to 59 minutes 1to 720 hours The p...

Страница 35: ...36 SP2602 User Manual Example Set dynamic report interval 1234 SVP 0 30S G H Disable static report interval 1234 SVP 1 1H G H...

Страница 36: ...37 SP2602 User Manual LED Indicator Behavior...

Отзывы: