05
Picture - 03
Cord With Grounding
Leveled working Surface
Motor Housing
Maximum height = 850mm
2. INSTALLATION AND PRE-OPERATION
2.1 Installation
The Food Processor should be placed on a leveled working surface ,
preferably 850 mm high above floor . Below the outlet, place a recipient to collect the
processed product .
Control the electricity source voltage , it shall be the same as the Food
Processor motor voltage, 110 or 220 V . The label stuck on the cord will give you the
right voltage.
The cord has a plug with two round pins and a grounding wire (earth wire) .
The three shall be well connected before to switch ON the machine .
2.2
Pre- Operation
Be sure the Food Processor is stable . Before to start operation wash the discs
and the grilles with hot water and neutral soap , rinse and dry before to replace them into
the machine .
2.3
Selecting the Discs and Grilles
To be supplied as optional a complete range of discs and grilles are at your
disposal , to process a wide vegetables and fruits products .
20
Problems
Causes
Solutions
* The cut product remains
inside the machine.
* The expeller dish is not in
place.
* Place the expeller dish, as
recommended at item 3,2
and 3,3l.
* The disc stops during
operation.
* Electric Failure.
* See if the machine cord
is plugged on its socket.
* Motor belts are sliding.
* T i g h t t h e b e l t i n
accordance with item 5,2l.
* The ram feed arm safety
device has a bad contact or
is out of order.
* Adust the safety device,
and check the electric
contacts.
* The frame lid safety device
has a bad contact.
* Call technical assistence.
* the ON/OFF switch has a
bad contact.
* Check the contacts.
* he plug or the cord has a
bad contact.
* Check the cord to find out
if there is an interruption,
and check the plug pins.
* The food Processor does
not start.
* Electricity shortage.
* Check electricity supply.