05
* Control if the filter is placed into its right place inside the Bowl .
* Fill the Bowl with 30 litres of water .
* Place the lid and tight the loops.
* After this , put the thermostat handle on 100 C position, and switch
ON the thermostat .
* Await one hour, and let the water flow out through the Outflow
Faucet .
* Using a clean and wet cloth , dry the Bowl and the Filter.
4.3.1 Advice
When checking the tension of the belts or chains, DO NOT introduce
your fingers between the belts , the chains, nor the gears.
4.3.2 Precautions
Check if motors, belts, chains or gears and the turning or sliding parts
of the machine produce abnormal noises .
Check the tension of the belts and chains and replace the set when
belt, chain or gears show signs of being worn out.
When checking tensions of belts or chain DO NOT introduce your
fingers between belts and pulleys , nor between the chains and gears. Check
protections and safety devices to make sure they are working properly.
4.3 Routine Inspection
4.2 Safety Procedures and Notes Before Turning Machine ON
IMPORTANT
Carefully read ALL INSTRUCTIONS of this manual before turning the machine
ON. Be sure to be familiar with the set and that you have well understood all
information contained in this manual. If you have any question contact your
supervisor or your nearest Dealer.
08
4 .2.1. Danger
An electric cable or electric wire with damaged insulation could cause electrical
shocks as well as electrical leak. Before use check conditions of all wires and
cables.
4 .2. 2 Advices
Be sure ALL INSTRUCTIONS in this manual have been thoroughly understood.
Every function and operational procedure have to be very clear to the operator.
Any manual command ( switch, button, or lever ) shall be given only after to be sure it
is the correct one .
4. 2. 3 Precautions
The electric cable has to be compatible with the power required by the machine,
Cables touching the floor or close to the machine need to be protected against short
circuits.
Oil reservoirs if any have to be full up to the required level as indicated. Check level
and add oil if necessary.
3. OPERATION
3.1 Operation Process
Observation : To start the heating the Bowl shall be full of Water .
* Control the electric installation in accordance with item 2.1.2
* Close the Outflow Faucet .
* Control whether the thermostat handle is placed on 0 C position , and if the
thermostat, the crushing and the centrifuge command switches are on position OFF .
* Control if the filter is correctly placed inside the bowl.
* To insert or withdraw the filter use the Filter Handle.
* Next step will depend on the chosen process .
* To start the heating process , place the key on the heating position, and place the
thermostat handle on the desired temperature .
Observation : only start the heating process with the bowl full of water or other liquid.
* Crushing and centrifuge steps may be started without previously go through the
heating step .
* The command key has four positions , as follows :
OFF , heating, crushing and centrifuge
When the key is placed on one of the four position, the chosen position will be
working , the other three are excluded.