I
3P37
Burner position
CO
M
%
CO
2M
%
CO
2N
%
AFCO %
Limit %
Pass or
Fail
C32
Rf gas, 1.05Rate
112
8.61
13.7
0.0178
0.1
Pass
Rf gas, Full Rate
41
7.71
13.7
0.0073
0.1
Pass
Rf gas, low
145
3.6
13.7
0.0552
0.2
Pass
Rf gas, Pn, 0.85V
65
8.22
13.7
0.0108
0.2
Pass
Rf gas, Pn, 1.10V
58
8.10
13.7
0.0098
0.2
Pass
C12
Rf gas, 1.05Rate
46
7.57
13.7
0.0083
0.2
Pass
Rf gas, Full Rate
32
7.17
13.7
0.0061
0.1
Pass
Rf gas, low
135
3.11
13.7
0.0595
0.1
Pass
Rf gas, Pn, 0.85V
31
7.33
13.7
0.0058
0.1
Pass
Rf gas, Pn, 1.10V
29
7.21
13.7
0.0055
0.2
Pass
I
3B/P30
, I
3+
Burner position
CO
M
%
CO
2M
%
CO
2N
%
AFCO %
Limit %
Pass or
Fail
C12
Rf gas, 1.05Rate
143
8.65
14
0.0231
0.2
Pass
Rf gas, Pn
99
8.02
14
0.0173
0.1
Pass
Rf gas, low
167
3.56
14
0.0657
0.1
Pass
Rf gas, Pn, 0.85V
51
7.69
14
0.0093
0.2
Pass
Rf gas, Pn, 1.10V
68
7.89
14
0.0121
0.2
Pass
Flame lift gas,
0.95Qmin
303
3.14
13.7
0.1322
0.2
Pass
C32
Rf gas, 1.05Rate
32
6.51
14
0.0069
0.2
Pass
Rf gas, Pn
31
6.49
14
0.0067
0.1
Pass
Rf gas, low
149
2.91
14
0.0717
0.1
Pass
Rf gas, Pn, 0.85V
35
6.70
14
0.0073
0.2
Pass
Rf gas, Pn, 1.10V
33
6.61
14
0.0070
0.2
Pass
G31, low
206
2.53
13.7
0.1115
0.2
Pass
Flame lift gas,
0.95Qmin
32
6.51
14
0.0069
0.2
Pass
25