24/24

Mounting_instructions_Flex_2.0

01/10/2021

Содержание iDome

Страница 1: ...01 10 2021 iDome iWindow Flex 2 0 Mounting instructions EN Art N 82671...

Страница 2: ...ts below the danger zones Before making the roof opening for the skylight barrel vault make sure there are safety nets conform to the current legislation The nets must be attached firmly and sufficien...

Страница 3: ...ossible Parts of more than 25 kg must be lifted with at least 2 persons Personal protective equipment Work clothes safety shoes and helmet are mandatory for everyone Lifeline and harness are mandatory...

Страница 4: ...ESTER CURB p 10 10 2 2 METAL CURB p 10 10 2 3 PVC CURB p 11 11 MOUNTING THE CHAIN BRACKET ON THE CURB p 11 11 1 LOCATION OF THE BRACKET p 11 11 1 1 SINGLE ACTUATOR THE CHAIN BRACKET IS POSITIONED IN T...

Страница 5: ...ody parts the zone of the openable section must always be avoided during installation Do not paint or lacquer the rain sensor Dirt on the rain sensor may cause operating problems Therefore it is recom...

Страница 6: ...mushroom head PH Blind rivet Self drilling hexagon washer head screw Cap nut M5 stainless steel Chain bracket Chain bracket screw M6x30 Cross recessed screw with raised countersunk head Phillips DIN9...

Страница 7: ...o be used with a PVC curb For a curb construction other than GRP or PVC other mounting hardware may be necessary 8 1 Curb construction The curb not included must comply with the following conditions U...

Страница 8: ...the roof 9 2 Minimum roof inclination iDome Pitched roof iDome roof inclination between 0 max 25 Hinges always on low side 9 3 Minimum roof inclination iWindow2 iWindow3 Pitched roof iWindow roof inc...

Страница 9: ...Flex 2 0 product includes mounting hardware for polyester metal or PVC curbs For other types of curbs or curbs with different flange dimensions Use suitable mounting hardware to attach the hinges 25 d...

Страница 10: ...les with a 5 5 mm drill bit Curb flange dimensions 10 2 2 Metal curb Use the supplied self drilling hexagon washer head screws 4 8 x 25 Curb flange dimensions 4 x 5 5 mm Daylight size polyester max 60...

Страница 11: ...ocation of the bracket Important notice The middle of the chain bracket must be placed 32 mm from the daylight size longest side Your Flex 2 0 product includes a chain bracket positioning tool which c...

Страница 12: ...Accurately mark the position with a marker 11 1 2 Double actuator the middle of the chain bracket is positioned 322 mm from the middle of the curb 2 x 2 x Accurately mark the 2 positions with a marker...

Страница 13: ...n the curb Your Flex 2 0 product includes mounting hardware for polyester metal or PVC curbs For different types of curbs or curbs with different flange dimensions Use suitable mounting hardware to at...

Страница 14: ...oduct is equipped with 1 electrical cable containing 6 cores This cable serves 2 purposes Providing 230 V AC power Connection to a switch to operate your Flex 2 0 product The cable comes out of the fr...

Страница 15: ...the rain sensor is stowed inside the skylight 13 1 Mounting rain sensor on bracket Before removing the skylight from the packaging Open up the side where the rain sensor is located in order to have ea...

Страница 16: ...cess cable into sensor Do not place the skylight with mounted rain sensor on the ground This can cause damage to the bracket and or rain sensor Keep the skylight with mounted rain sensor in the box un...

Страница 17: ...ly secured with the supplied threaded rod and two cap nuts These can be made burglar proof by adding a drop of Loctite to the cap nuts This glue application may also help to prevent incorrect opening...

Страница 18: ...etal curb Use the cable routing as a guide Use the included M4 bolts and nuts to drill 2 holes in the curb to fix the cable routing PVC curb No pre drilling needed Use the included screws to fix the c...

Страница 19: ...out approximately 10 cm This is done so you do not need to have mains power to mount the chain to the bracket Remove any protection foam from the chain CAUTION crushing hazard Safely place temporary s...

Страница 20: ...osition when not pressed Connect the grey GY wire to the live wire of your 230 V mains power Connect the blue BU wire to the neutral wire of your 230 V mains power Connect the green yellow GN YE wire...

Страница 21: ...wire as open ends Connect the live wire of your 230 V mains power to the COM contact of your switch Connect the blue BU wire to the neutral wire of your 230 V mains power Connect the green yellow GN...

Страница 22: ...opened manually WARNING the Multiform is not suited for frequent roof access iWindow2 3 Flex glass skylight Remove all protective foil and stickers with tips maintenance tips and tips for the installe...

Страница 23: ...y Single actuator 230 V AC 600 N 600 N 250 mm 12 5 mm s Second actuator 24 V DC 600 N 600 N 250 mm 12 5 mm s For Flex 2 0 with 2 actuators Voltage 230 V AC 10 50 H Leakage current 2 mA 240 V AC Open c...

Страница 24: ...24 24 Mounting_instructions_Flex_2 0 01 10 2021...