SkyJuice SkyHydrant Скачать руководство пользователя страница 3

 

Chemical Cleaning undertaken monthly (continued) 

 

1)  Undertake a “Manual Clean Procedure” but leave the unit empty (do not refill). 
2)  Add water to the Chlorine Tank until ¾ full.  
3)  Add chlorine to the chlorine tank (see teaspoon amounts below) and use a mixing stick to stir 

until dissolved: 

 

2 Teaspoons 

of Chlorine powder with 65% 

available chlorine (700g / kg). 

OR 

3 Teaspoons 

of Chlorine powder with 55% 

available chlorine (550g / kg). 

OR

 

4 Teaspoons of

 Chlorine powder with 35% 

available chlorine (350g / kg). 

OR 

6 Teaspoons 

of Chlorine powder with 25% 

available chlorine (250g / kg). 

 

OR

 

100 Millilitres

 of Liquid chlorine (Sodium 

Hypochlorite) with 12% available chlorine. 

 

4) Open 

T5

 (chlorine) to allow the 

chlorine tank

 to drain,

 

than close 

T5.

 

5)  Fill the SkyHydrant with water by opening 

T1

 & 

T4

 until water flows out of 

T4

 than close both 

taps. 

6)  Move the Cleaning Handles back and forth a few times to mix the chlorine inside the unit 

than leave to 

soak for at least 2 hours

7)  After soaking, undertake a “Manual Clean” to remove the chlorine solution. 
8)  The “Chemical Cleaning” is now complete. The unit can again be refilled water. 

 

Chemical Cleaning using Citric Acid.

 If high levels of Iron are present undertake periodic 

chemical cleaning using 500 grams of Citric Acid instead of chlorine. Citric acid cleaning is 
undertaken in addition to the regular chemical cleaning program using chlorine. 

 

How the SkyHydrant works. 

The SkyHydrant water purification unit requires no power to operate instead it relies on gravity water 
pressure. Raw water flows through the unit with a water head pressure of between 2 metres and 
maximum 4 metres (0.2 bar to 0.4 bar or 3 psi to 6 psi) to produce a typical flow rate of about 700 litres 
of drinking water per hour (subject to the quality of source raw water).  

 

There are many 
ways of setting up 
SkyHydrant water 
purification plants. 
A popular method 
is to pump raw 
water (using 
mechanical or 
hand pump) to a 
1,000 liter header 
tank on a 3 meter 
high tank-stand 
and allow the 
water to gravity 
feeding down 
through the 

SkyHydrant into a lower 1,000-liter drinking water tank located on a 1-meter high tank-stand.  

 

The drinking water tank can be connected with taps or be connected with pipes for supplying drinking 
water directly to houses or to a distribution network.  

 

Never pump or connect mains water pressure directly to the SkyHydrant water purification unit without 
using a suitable water pressure regulating or control device as excessive water pressure may damage 
the filter fibres.  
 

 