SkyJuice SkyHydrant Скачать руководство пользователя страница 1

                                                         

 
The SkyHydrant water purification unit provides a stand-alone system for supplying clean safe drinking 
water for disasters, emergencies and humanitarian programs.  
 
Operations are manual and simple and the unit can be set up for use in refugee camps, communities, 
villages, health clinics, schools, orphanages and many other 
applications where the source water is not safe.   

 

Where to set-up the SkyHydrant  

To avoid theft or vandalism select a secure location to install the 
SkyHydrant sheltered from the sun, wind and rain. 

  Mount the SkyHydrant in a sturdy position with sufficient 

space around the unit to allow for cleaning  

  Allow space for access for people to line up and collect the 

water. Ensure location is clean and well drained and provide 
a disposal area (drain) for backwash water. 

  The SkyHydrant unit is a valuable asset and requires daily 

cleaning for its continued operation. A local supervisor 
should be appointed to oversee operations and provide 
security. A daily operational log of water production should 
also be maintained. 

 

Assembling the SkyHydrant  

Attach the Cleaning Handle to the top of the SkyHydrant. One 
handle is already located in position and the other needs to be 
screwed into place.

 

 

 
The SkyHydrant can be set up to operate as either a wall mounted 
unit using the brackets supplied or as a freestanding unit using the 
aluminium legs supplied. Bolts and screws are included in the 
accessory kit allowing the brackets or legs to be easily connected.  
 
All fittings use 20mm (3/4”) connectors and lengths of flexible 
hoses, clamps and fittings are supplied to assist with setting up and 
connecting pipes. Taps 

T1

 and 

T2

 are adjustable allowing them to 

be folded down level.  
 
Connect required operating equipment to allow the SkyHydrant to 
function – this may include hoses, pipes, water tanks, pump and 
other equipment. 
 
Connect the dirty (raw) water pipe to (

T1

) connect the backwash 

pipe to 

T2

 and connect the drinking water outlet pipe to 

(T3)

.  

 
It is good practice to soak and flush drinking containers, hoses, 
taps, and other equipment with a 0.1% (1,000 parts per million) 
chlorine solution to eliminate any residual or accidental 
contamination - add approximately 1 teaspoon of chlorine powder 
to 5 litres of water.   
   

 

SKYHYDRANT™ SET UP AND OPERATING INSTRUCTIONS 

Отзывы: