SJIII Series E -
The CONVENTIONALS
118931AH
May 2002
SECTION 2, Page 24
BATTERY STATUS
1. GREEN LED ..................... CHARGE COMPLETE
2. YELLOW LED ................................ 80% CHARGE
3. RED LED ....................................... INCOMPLETE
CHARGER STATUS
4. YELLOW LED ............................... CHARGER ON
5. RED LED ............................. ABNORMAL CYCLE
6. CHARGER STOP SWITCH
7. FUSE HOLDER
This charger is equipped with an electronic circuit
that will completely recharge the batteries and
automatically turn off after the charge cycle is
complete.
7
6
5
4
3
2
1
MAC Charger Operation (#BA1001)
The function of the LED indicators is as follows:
When the AC power is connected to the charger, the
LED’s will flash several times then flash independently
to check the light circuits. After the flashing sequence
is complete the “INCOMPLETE” light will come on.
Five seconds later, the “CHARGER ON” light will come
on and at the same time, the ammeter will indicate
how much current is going to the batteries.
As the charge cycle continues, which can last between
1-1/2 hours and 16 hours for a complete cycle,
depending on the state of charge of the batteries, the
“80% CHARGE” light will come on and the
“INCOMPLETE” light will go off. When voltage of the
batteries reaches approximately 60 volts, the “80%
CHARGE” light will go off and the “CHARGE
COMPLETE” light will come on. This light will remain
on even after the charger is turned off by the electronic
control. After the charger turns off, the “CHARGE
COMPLETE” light will indicate to the operator that
the batteries are healthy and are fully charged.
If the “80% CHARGE” light continues to stay on after
the charge cycle is complete, this indicates to the
operator that the batteries are not capable of attaining
a full charge.
If the “INCOMPLETE” light remains on after the charge
cycle is complete, this indicates to the operator that
the batteries are not capable of attaining even an 80%
charge.
If either the “80% CHARGE” or “INCOMPLETE” light
remain on after the charge cycle is complete, the
batteries should be inspected for problems.
Your standard good watering procedures should be
used at all times.
Figure 2-16. A
utomatic Battery Charger
MAC #BA1045 continued...
If the charger is restarted on a fully charged battery
pack, the 80% and the “ ” (CHARGER ON) lights will
illuminate for approximately 70 minutes. After 70
minutes, the 100% (COMPLETE) light will be
illuminated. The charger has a 20 hour timer. If the
batteries do not reach approximately 2.55 volts per
cell in 20 hours, the “
” (ABNORMAL) and the 80%
lights will be illuminated. To restart the charger,
disconnect then reconnect the AC power cord and
another 20 hour charging cycle will begin.
This charger has an automatic circuit that allows
operation at any input voltage and either 50Hz or
60Hz.
Refer to “Battery Service And Charging Procedures”
for proper battery inspection and maintenance
procedures.