98
SJ519 TH
216942AC
Section 4 – Procedures
Non-Routine Maintenance
DRIVE CONTROLLER ERROR CODES
DTC
#
SPN
FMI
Description
Fault Conditions
Potential Cause
1
91
12
Accelerator Pedal Posi-
tion 1 Failure
Pedal voltage greater than 1V and neutral
switch reads 'neutral'
Wiring problem,
faulty pedal
3
127
0
Transmission Pressure
High
Engine running (>500 rpm) and either pres-
sure transducer reading is higher than 7300
psi for 3 seconds
Faulty sensor or hy-
draulic system failure
4
127
2
Transmission Pressure
Sensors Erractic, Intermit-
tent, Or Incorrect
Both pressure sensors reading greater than
1v
Faulty sensor or
short in wiring
5
127
7
Transmission Pressure
Sensors Not Responding
Properly
Engine is running (>500 rpm)
and machine is in forward,
Pump displacement > 0.9, And
P port pressure > (N port p270) psi
or
machine is in reverse,
Pump displacement < -0.9, And
N port pressure > (P port pr 270)
Pressure sensor con-
nectors are swapped
6
127
18
Transmission Pressure
Low
Park brake engaged
and
engine is running (>500 rpm)
and either pressure transducer reading is
lower than 200 psi for 5 seconds
Faulty sensor, charge
relief valve stuck
open
7
639
19
J1939 Network 1 (Engine
Comm) Data Error
Loss of communication with engine ecu for
greater than 500ms
Canbus wiring, ecu
power
8
741
3
Transmission Forward
Solenoid Voltage Above
Normal
Measured voltage is greater than expected
Solenoid output
shorted to power
9
741
5
Transmission Forward
Solenoid Current Below
Normal
Measured current is less than expected
Open circuit
10
741
6
Transmission Forward
Solenoid Current Above
Normal
Measured current is greater than expected
Wiring problem,
faulty solenoid
11
751
12
Transmission Primary
Shift Selector Failure
Forward and reverse signals are both 'on'
Wiring problem,
faulty fnr switch
12
761
3
Transmission Forward
Pressure Sensor Voltage
Above Normal
Measured voltage is greater than expected
Wiring problem,
faulty sensor
13
761
4
Transmission Forward
Pressure Sensor Voltage
Below Normal
Measured voltage is less than expected
Wiring problem,
faulty sensor
14
763
3
Transmission Reverse
Pressure Sensor Voltage
Above Normal
Measured voltage is greater than expected
Wiring problem,
faulty sensor
15
763
4
Transmission Reverse
Pressure Sensor Voltage
Below Normal
Measured voltage is less than expected
Wiring problem,
faulty sensor
16
785
2
Transmission Hydraulic
System Feedback Er-
ractic, Intermittent, Or
Incorrect
Pump swash traveling the wrong direction
Contamination, me-
chanical failure
Содержание SJ519 TH
Страница 1: ...SERVICE MANUAL 216942AC October 2020 ANSI SJ519 TH TELEHANDLERS...
Страница 4: ...4 SJ519 TH 216942AC Notes...
Страница 22: ...22 SJ519 TH 216942AC Section 1 Scheduled Maintenance Function Tests...
Страница 23: ...23 SJ519 TH 216942AC Section 2 Maintenance Tables...
Страница 34: ...34 SJ519 TH 216942AC Notes...
Страница 35: ...35 SJ519 TH 216942AC Section 3 System Component Identification and Schematics...
Страница 40: ...40 SJ519 TH 216942AC Notes...
Страница 107: ......
Страница 108: ...www skyjack com...